Worked example

Boost pressure above the high-side rating

At 3:1 the ideal boost crosses the entered 5,000 psi limit. Check the entire high-pressure side, including relief and isolated cavities.

Inputs

:1
psi
GPM
psi
psi
Use the actual differential across the relief valve.
lb/ft³
BTU/lb·°F
°F
°F

Anatomy

Area-ratio intensifier and relief temperature rise
Area-ratio intensifier and relief temperature riseBOOST PRESS.6600psiOUTLET FLOW4GPMOIL TEMP RISE20.74°FSEAL MARGIN19.26°FInlet pistonBoosted oilRelief valveOil warmingReturnPressureReturnTank / suctionBoost pressure / entered rating132%0%100% reference150%

Results

US customary

Boosted pressure exceeds the entered high-side rating. Check the complete high-pressure path and relief protection.

Ideal boosted pressure6,600psi455.054bar
Ideal high-side flow4GPM15.142LPM
Ideal transmitted power15.4HP
Calculated single-pass rise20.744°F11.524°C
Field estimate · ΔP/15018.667°F10.37°C
Oil temperature after relief140.744°F
Temperature below seal limit19.256°F

Worked calculation

  1. Pressure multiplication

    R = A_low/A_high. Ideal pressure out = R × pressure in. Ideal flow out = flow in/R. Pressure × flow is conserved in this model.

  2. Single-pass heat balance

    ΔT = ΔP/(ρ × c_p) with Pa, kg/m³ and J/kg·K. Add the resulting temperature difference to the inlet temperature.

  3. Field approximation

    ΔT (°F) ≈ ΔP (psi)/150. Compare to the calculation using the entered oil properties and check the seal limit at the predicted outlet temperature.

Results for the original example inputs
Ideal boosted pressure6,600psi
Ideal high-side flow4GPM
Calculated single-pass rise20.744°F
Field estimate · ΔP/15018.667°F
Oil temperature after relief140.744°F
Temperature below seal limit19.256°F

Uses ideal same-stroke area multiplication and negligible inlet backpressure on the intensifier’s return side. Real output depends on leakage and refill duty. The relief model treats lost pressure energy as sensible heat in a single oil pass.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.