Worked example
Warm inlet oil near the seal limit
Even a moderate relief pressure drop can consume the remaining temperature margin when oil enters hot.
Inputs
Anatomy
Area-ratio intensifier and relief temperature riseResults
US customaryPost-drop oil meets or exceeds the entered seal temperature limit. Elevated temperature can degrade seals and shorten oil life.
| Ideal boosted pressure | 3,800psi262.001bar |
|---|---|
| Ideal high-side flow | 4GPM15.142LPM |
| Ideal transmitted power | 8.867HP |
| Calculated single-pass rise | 20.003°F11.113°C |
| Field estimate · ΔP/150 | 18°F10°C |
| Oil temperature after relief | 170.003°F |
| Temperature below seal limit | -10.003°F |
Worked calculation
Pressure multiplication
R = A_low/A_high. Ideal pressure out = R × pressure in. Ideal flow out = flow in/R. Pressure × flow is conserved in this model.
Single-pass heat balance
ΔT = ΔP/(ρ × c_p) with Pa, kg/m³ and J/kg·K. Add the resulting temperature difference to the inlet temperature.
Field approximation
ΔT (°F) ≈ ΔP (psi)/150. Compare to the calculation using the entered oil properties and check the seal limit at the predicted outlet temperature.
| Ideal boosted pressure | 3,800psi |
|---|---|
| Ideal high-side flow | 4GPM |
| Calculated single-pass rise | 20.003°F |
| Field estimate · ΔP/150 | 18°F |
| Oil temperature after relief | 170.003°F |
| Temperature below seal limit | -10.003°F |
Uses ideal same-stroke area multiplication and negligible inlet backpressure on the intensifier’s return side. Real output depends on leakage and refill duty. The relief model treats lost pressure energy as sensible heat in a single oil pass.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.