Worked example

Ideal pump efficiency baseline

Setting both efficiencies to 100% gives equal shaft and hydraulic powers and zero modeled pump heat. Compare with the same pump at measured efficiencies.

Inputs

RPM
in³/rev
psi
Use the pressure rise across the pump if inlet pressure is appreciable.
%
%

Anatomy

Positive-displacement pump power balance
Positive-displacement pump power balanceOUTLET FLOW9.091GPMSHAFT INPUT9.545HPOIL OUTPUT9.545HPWASTE HEAT0BTU/hrMPrime mover1500 RPMPumpOil outputPump heatPressureReturnTank / suctionDischarge / planning ceiling36%0%100% reference150%

Results

US customary
Actual outlet flow9.091GPM
Theoretical flow9.091GPM
Pump displacement1.4in³/rev
Hydraulic output power9.545HP7.118kW
Required shaft power9.545HP7.118kW
Pump waste heat0BTU/hr0kW
Volumetric loss0BTU/hr
Mechanical loss0BTU/hr
Overall efficiency100%

Worked calculation

  1. Flow and displacement

    Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).

  2. Prime-mover power

    P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).

  3. Pump heat

    Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.

Results for the original example inputs
Pump displacement1.4in³/rev
Theoretical flow9.091GPM
Actual outlet flow9.091GPM
Overall efficiency100%
Required shaft power9.545HP
Pump waste heat0BTU/hr

Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.