Worked example

2,200 RPM mobile power unit

This high-speed operating point illustrates how much shaft power and pump heat come with increased flow at fixed pressure.

Inputs

RPM
in³/rev
psi
Use the pressure rise across the pump if inlet pressure is appreciable.
%
%

Anatomy

Positive-displacement pump power balance
Positive-displacement pump power balanceOUTLET FLOW23.83GPMSHAFT INPUT52.68HPOIL OUTPUT41.71HPWASTE HEAT27.9kBTU/hrMPrime mover2200 RPMPumpOil outputPump heatPressureReturnTank / suctionDischarge / planning ceiling60%0%100% reference150%

Results

US customary
Actual outlet flow23.833GPM
Theoretical flow26.19GPM
Pump displacement2.75in³/rev
Hydraulic output power41.708HP31.102kW
Required shaft power52.682HP39.285kW
Pump waste heat27,921.746BTU/hr8.183kW
Volumetric loss10,495.789BTU/hr
Mechanical loss17,425.958BTU/hr
Overall efficiency79.17%

Worked calculation

  1. Flow and displacement

    Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).

  2. Prime-mover power

    P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).

  3. Pump heat

    Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.

Results for the original example inputs
Pump displacement2.75in³/rev
Theoretical flow26.19GPM
Actual outlet flow23.833GPM
Overall efficiency79.17%
Required shaft power52.682HP
Pump waste heat27,921.746BTU/hr

Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.

The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.