Worked example
Ideal pump efficiency baseline
Setting both efficiencies to 100% gives equal shaft and hydraulic powers and zero modeled pump heat. Compare with the same pump at measured efficiencies.
Inputs
Anatomy
Positive-displacement pump power balanceResults
US customary| Actual outlet flow | 9.091GPM |
|---|---|
| Theoretical flow | 9.091GPM |
| Pump displacement | 1.4in³/rev |
| Hydraulic output power | 9.545HP7.118kW |
| Required shaft power | 9.545HP7.118kW |
| Pump waste heat | 0BTU/hr0kW |
| Volumetric loss | 0BTU/hr |
| Mechanical loss | 0BTU/hr |
| Overall efficiency | 100% |
Worked calculation
Flow and displacement
Q_theoretical = D × RPM/60 in m³/s. Q_actual = η_v × Q_theoretical. For a flow target, D = Q_actual × 60/(RPM × η_v).
Prime-mover power
P_hydraulic = ΔP × Q_actual. P_shaft = P_hydraulic/(η_v × η_m). In US units, HP_shaft ≈ GPM_actual × PSI/(1714 × η_total).
Pump heat
Pump heat = P_shaft − P_hydraulic. The model separates leakage loss ΔP × (Q_theoretical − Q_actual) and mechanical loss P_shaft − ΔP × Q_theoretical.
| Pump displacement | 1.4in³/rev |
|---|---|
| Theoretical flow | 9.091GPM |
| Actual outlet flow | 9.091GPM |
| Overall efficiency | 100% |
| Required shaft power | 9.545HP |
| Pump waste heat | 0BTU/hr |
Steady positive-displacement pump at the entered point. Use measured efficiencies from the pump map at the actual speed, pressure, viscosity and displacement. The shaft requirement excludes drive and motor electrical losses.
The calculator uses US fluid-power conventions for mechanical horsepower and US gallons, and SI base units for the model. See the methodology and rounding rules.