Distributed sign wash modules

Give each LED its own thermal path. Parallel strings increase total driver load while each local sink still carries a single module’s heat.

Constant-current driver
V
Nominal value at 25 °C / 77 °F.
mV/°F
A
V
Ambient and thermal path
°F
°F
°F/W
°F/W
°F/W
°F
Cold string
24.75V
AC input
43.8W
Junction
116.6°F
Thermal margin
104.4°F

Driver and thermal stack

Edit inputs ↓
Driver and thermal stackCONSTANT CURRENTTHERMAL STACKJunction116.6 °FCase110.8 °FHeat sink109.3 °FAmbient100.4 °FCC DRIVER8S × 3PCold-start string voltage24.75 V
The package and interface carry one module’s heat. A shared sink carries the heat from every module.

Driver and thermal limits

Within screen
OutsideThresholdWithin
  • Driver voltage24.75 / ≤ 29 V within screen
  • Junction rise above ambient16.18 / ≤ 120.6 °F within screen

Heat uses the larger modeled forward drop at maximum ambient or the junction limit. This bounds heat while the junction stays within the selected limit.

Additional readings
Nominal string voltage24.16V
Cold-start driver headroom4.25V
Highest screened string voltage24.75V
Driver margin over screened range4.25V
Nominal electrical power per string13.29W
Nominal DC load, all strings39.86W
Cold-start AC estimate at nominal efficiency44.88W
Estimated heat per LED1.07W
Heat sink temperature109.3°F
LED case temperature110.8°F
Effective module-to-ambient resistance15.12°F/W

Worked calculation

US customary results for the original preset.

  1. Apply the forward-voltage slope at 10.4 °F to get a cold string voltage of 24.75 V and 4.25 V of cold-start headroom.
  2. The nominal DC load is 39.9 W. At the entered efficiency, the estimated AC input is 43.8 W.
  3. Multiply 1.07 W per LED by the effective thermal resistance, then add maximum ambient to get 116.6 °F.

Calculation method

Use the data-sheet forward voltage at rated current, including bin tolerances where known. Select the heat sink arrangement that matches the luminaire.

Voltage and nominal power
Vf(T) = Vf,25 + β(T − 25 °C) · PDC = Ns × Np × If × Vf,25
Heat generated per LED
Pheat = If × Vf,heat × (1 − radiant fraction)
Thermal path and wall power
Tj = Ta,max + Pheat × (Rθjc + Rθcs + M × Rθsa) · PAC = PDC/η

Check current sharing, driver minimum output voltage and start-up behavior, LED bin variation, and actual assembly thermal resistance.

Sources and assumptions ↗