Freezer aisle cold start
Test a long series string against limited voltage at cold start. The selected driver passes near room temperature and runs short at the freezer ambient.
Inputs
View results ↑- Cold string
- 51.1V
- AC input
- 29.5W
- Junction
- 79.2°F
- Thermal margin
- 141.8°F
Driver and thermal stack
Edit inputs ↓Driver and thermal limits
Review needed- Driver voltage51.1 / ≤ 50 V outside screen
- Junction rise above ambient11.25 / ≤ 153 °F within screen
Heat uses the larger modeled forward drop at maximum ambient or the junction limit. This bounds heat while the junction stays within the selected limit.
Additional readings
| Nominal string voltage | 48.8V |
|---|---|
| Cold-start driver headroom | -1.1V |
| Highest screened string voltage | 51.1V |
| Driver margin over screened range | -1.1V |
| Nominal electrical power per string | 26.84W |
| Nominal DC load, all strings | 26.84W |
| Cold-start AC estimate at nominal efficiency | 30.89W |
| Estimated heat per LED | 1.18W |
| Heat sink temperature | 72.5°F |
| LED case temperature | 73.9°F |
| Effective module-to-ambient resistance | 9.54°F/W |
Worked calculation
US customary results for the original preset.
- Apply the forward-voltage slope at -31 °F to get a cold string voltage of 51.1 V and -1.1 V of cold-start headroom.
- The nominal DC load is 26.8 W. At the entered efficiency, the estimated AC input is 29.5 W.
- Multiply 1.18 W per LED by the effective thermal resistance, then add maximum ambient to get 79.2 °F.
Calculation method
Use the data-sheet forward voltage at rated current, including bin tolerances where known. Select the heat sink arrangement that matches the luminaire.
- Voltage and nominal power
- Vf(T) = Vf,25 + β(T − 25 °C) · PDC = Ns × Np × If × Vf,25
- Heat generated per LED
- Pheat = If × Vf,heat × (1 − radiant fraction)
- Thermal path and wall power
- Tj = Ta,max + Pheat × (Rθjc + Rθcs + M × Rθsa) · PAC = PDC/η
Check current sharing, driver minimum output voltage and start-up behavior, LED bin variation, and actual assembly thermal resistance.
Sources and assumptions ↗Freezer aisle cold start
Inputs
| LEDs in series | 16 |
|---|---|
| Parallel strings | 1 |
| Reference forward voltage | 3.05V |
| Forward-voltage slope | -1.3333333mV/°F |
| Current per string | 0.55A |
| Maximum driver voltage | 50V |
| Driver efficiency | 0.91 |
| Minimum start ambient | -31°F |
| Maximum operating ambient | 68°F |
| Radiant power fraction | 0.3 |
| Heat sink arrangement | One heat sink per LED |
| Junction-to-case resistance | 4.5°F/W |
| Case-to-sink resistance | 1.26°F/W |
| Sink-to-ambient resistance | 3.78°F/W |
| Maximum junction temperature | 221°F |
Results
| Cold string | 51.1V |
|---|---|
| AC input | 29.5W |
| Junction | 79.2°F |
| Thermal margin | 141.8°F |
| Nominal string voltage | 48.8V |
| Cold-start driver headroom | -1.1V |
| Highest screened string voltage | 51.1V |
| Driver margin over screened range | -1.1V |
| Nominal electrical power per string | 26.84W |
| Nominal DC load, all strings | 26.84W |
| Cold-start AC estimate at nominal efficiency | 30.89W |
| Estimated heat per LED | 1.18W |
| Heat sink temperature | 72.5°F |
| LED case temperature | 73.9°F |
| Effective module-to-ambient resistance | 9.54°F/W |
Driver and thermal limits
- Driver voltage · 51.1 / ≤ 50 V · Outside screen
- Junction rise above ambient · 11.25 / ≤ 153 °F · Within screen
Heat uses the larger modeled forward drop at maximum ambient or the junction limit. This bounds heat while the junction stays within the selected limit.
Check current sharing, driver minimum output voltage and start-up behavior, LED bin variation, and actual assembly thermal resistance.