Freezer aisle cold start

Test a long series string against limited voltage at cold start. The selected driver passes near room temperature and runs short at the freezer ambient.

Constant-current driver
V
Nominal value at 25 °C / 77 °F.
mV/°F
A
V
Ambient and thermal path
°F
°F
°F/W
°F/W
°F/W
°F
Cold string
51.1V
AC input
29.5W
Junction
79.2°F
Thermal margin
141.8°F

Driver and thermal stack

Edit inputs ↓
Driver and thermal stackCONSTANT CURRENTTHERMAL STACKJunction79.2 °FCase73.9 °FHeat sink72.5 °FAmbient68 °FCC DRIVER16S × 1PCold-start string voltage51.1 V
The package and interface carry one module’s heat. A shared sink carries the heat from every module.

Driver and thermal limits

Review needed
OutsideThresholdWithin
  • Driver voltage51.1 / ≤ 50 V outside screen
  • Junction rise above ambient11.25 / ≤ 153 °F within screen

Heat uses the larger modeled forward drop at maximum ambient or the junction limit. This bounds heat while the junction stays within the selected limit.

Additional readings
Nominal string voltage48.8V
Cold-start driver headroom-1.1V
Highest screened string voltage51.1V
Driver margin over screened range-1.1V
Nominal electrical power per string26.84W
Nominal DC load, all strings26.84W
Cold-start AC estimate at nominal efficiency30.89W
Estimated heat per LED1.18W
Heat sink temperature72.5°F
LED case temperature73.9°F
Effective module-to-ambient resistance9.54°F/W

Worked calculation

US customary results for the original preset.

  1. Apply the forward-voltage slope at -31 °F to get a cold string voltage of 51.1 V and -1.1 V of cold-start headroom.
  2. The nominal DC load is 26.8 W. At the entered efficiency, the estimated AC input is 29.5 W.
  3. Multiply 1.18 W per LED by the effective thermal resistance, then add maximum ambient to get 79.2 °F.

Calculation method

Use the data-sheet forward voltage at rated current, including bin tolerances where known. Select the heat sink arrangement that matches the luminaire.

Voltage and nominal power
Vf(T) = Vf,25 + β(T − 25 °C) · PDC = Ns × Np × If × Vf,25
Heat generated per LED
Pheat = If × Vf,heat × (1 − radiant fraction)
Thermal path and wall power
Tj = Ta,max + Pheat × (Rθjc + Rθcs + M × Rθsa) · PAC = PDC/η

Check current sharing, driver minimum output voltage and start-up behavior, LED bin variation, and actual assembly thermal resistance.

Sources and assumptions ↗