MotionMechLab

Step frequency at 1/256 microstepping

See the pulse-rate cost of 1/256 input microstepping on a GT2 20T axis and compare it with a controller ceiling.

Jump to results ↓

Inputs

Motor & transmission
°
mm
T
Motion & load
rpm
kg
mm/s²
N
Include drag and any gravity load on the driven axis.
%
kg·cm²
Motor rotor plus drivetrain inertia seen at the motor.
×
kHz
Enter 0 to skip the controller limit check.
Pull-out curve samples

Replace these example points with data for your motor, current, driver and supply voltage.

rpm
N·m
rpm
N·m

Results

Preset estimate
Commanded resolution
1,280steps/mm
  • Step frequency exceeds the entered controller ceiling.
Pull-out torque between the two entered speeds, with the required operating point markedN·m0.47001,272 rpm
Teal marks the entered pull-out interval. The orange point marks required torque with margin.
Motor speed
450 rpm
Axis speed
300 mm/s
Axis feed
18,000 mm/min
Step frequency
384 kHz
Required pull-out torque
0.1163 N·m
Required torque (imperial)
16.46 oz·in
Pull-out torque at speed
0.3277 N·m
Travel per turn
40 mm
Required sizing power
5.48 W
Shaft power before margin
3.65 W
Axis force during acceleration
11.25 N
Rated frame face (nominal)
NEMA 17 · 42 mm
Full steps per revolution
200 steps

Worked example

A 1.8° motor at 1/256 takes 51,200 input steps per turn. On a 20T GT2 pulley the result is 1,280 steps/mm. At 300 mm/s the controller would need 384 kHz.

The entered ceiling is 150 kHz, below the requested pulse rate. If the driver supports internal interpolation, the controller can send fewer pulses while the driver smooths current between them. Enter the subdivision seen at the step pin.

Commanded resolution 1,280 steps/mm

Formulas

  • Full steps per turn = 360° / step angle
  • Travel per turn = pulley teeth × pitch, or screw lead
  • Steps/mm = full steps × microsteps / travel (mm)
  • Axis speed (mm/s) = RPM × travel / 60
  • Pulse frequency (kHz) = speed × steps/mm / 1000
  • Shaft torque = (m a + F) × travel / (2π η) + J × 2π a / travel
  • Required pull-out torque = shaft torque × margin factor
  • Mechanical power (W) = shaft torque × 2π RPM / 60

References

Frequently asked questions

What is the axis speed at 150 kHz with 1,280 steps/mm?

The pulse ceiling alone corresponds to 150,000 ÷ 1,280 = 117.19 mm/s. Pull-out torque and other limits can reduce speed further.

Which microsteps should I use when a driver interpolates internally?

Use the input subdivision that the driver expects from the controller. Its internal interpolation value is a separate driver setting.