Calculate from the transmission and the load
Steps per millimeter come from motor step angle, driver microstep setting and travel per motor revolution. A finer microstep setting raises the controller pulse rate. The theoretical step increment does not describe repeatability or positioning accuracy.
Size the motor against pull-out torque at the operating speed. NEMA 17, 23 and 34 identify the mounting envelope. The preset curve points illustrate the comparison and do not represent a rated motor. Enter two pull-out measurements at the intended voltage, current and driver, close to the target RPM.
Shaft torque includes linear acceleration, the resisting force you enter, transmission loss and the acceleration of rotating inertia. Use the margin-adjusted torque for motor comparison. Mechanical shaft power is distinct from electrical driver power.
Worked example
A 1.8° motor running at 1/16 microstepping with a GT2 20T pulley makes 3,200 command steps per revolution. It travels 40 mm per turn, so the axis uses 80 steps/mm. At 600 RPM the axis moves at 400 mm/s and the controller sends 32 kHz.
Formulas
Full steps per turn = 360° / step angleTravel per turn = pulley teeth × pitch, or screw leadSteps/mm = full steps × microsteps / travel (mm)Axis speed (mm/s) = RPM × travel / 60Pulse frequency (kHz) = speed × steps/mm / 1000Shaft torque = (m a + F) × travel / (2π η) + J × 2π a / travelRequired pull-out torque = shaft torque × margin factorMechanical power (W) = shaft torque × 2π RPM / 60