TR8×2 Z-axis resolution and motor RPM

Calculate steps/mm and motor RPM for a 2 mm lead TR8×2 Z screw. Compare its command scaling with a multi-start screw.

Jump to results ↓

Inputs

Motor & transmission
°
mm/rev
Motion & load
mm/s
kg
mm/s²
N
Include drag and any gravity load on the driven axis.
%
kg·cm²
Motor rotor plus drivetrain inertia seen at the motor.
×
kHz
Enter 0 to skip the controller limit check.
Pull-out curve samples

Replace these example points with data for your motor, current, driver and supply voltage.

rpm
N·m
rpm
N·m

Results

Preset estimate
Commanded resolution
1,600steps/mm
Pull-out torque between the two entered speeds, with the required operating point markedN·m0.47001,272 rpm
Teal marks the entered pull-out interval. The orange point marks required torque with margin.
Motor speed
300 rpm
Axis speed
10 mm/s
Axis feed
600 mm/min
Step frequency
16 kHz
Required pull-out torque
0.0309 N·m
Required torque (imperial)
4.38 oz·in
Pull-out torque at speed
0.3673 N·m
Travel per turn
2 mm
Required sizing power
0.97 W
Shaft power before margin
0.65 W
Axis force during acceleration
14.85 N
Rated frame face (nominal)
NEMA 17 · 42 mm
Full steps per revolution
200 steps

Worked example

On a 2 mm lead TR8×2, 3,200 pulses per revolution give 1,600 steps/mm. A 10 mm/s Z move takes 300 rpm. The same speed on TR8×8 takes 75 rpm.

Consider the lower lead when the axis needs more force from each unit of motor torque. Check the higher required motor speed and the efficiency of the screw and nut. Back-driving behavior depends on friction and the actual lead angle.

Commanded resolution 1,600 steps/mm

Formulas

  • Full steps per turn = 360° / step angle
  • Travel per turn = pulley teeth × pitch, or screw lead
  • Steps/mm = full steps × microsteps / travel (mm)
  • Axis speed (mm/s) = RPM × travel / 60
  • Pulse frequency (kHz) = speed × steps/mm / 1000
  • Shaft torque = (m a + F) × travel / (2π η) + J × 2π a / travel
  • Required pull-out torque = shaft torque × margin factor
  • Mechanical power (W) = shaft torque × 2π RPM / 60

References

Frequently asked questions

What Marlin Z scaling fits a 2 mm lead at 1/16?

For a 200-full-step motor, use 1,600 steps/mm as the starting Z value.

How can I distinguish TR8×2 from TR8×8 by travel?

Turn the shaft once while measuring nut travel. A 2 mm advance indicates TR8×2 and 8 mm indicates TR8×8.