ASME V Article 4

Matched impedance calibration pair

A custom wedge at 3,000 m/s and 2 g/cm³ is paired with a custom part at 6,000 m/s and 1 g/cm³.

Reading the result. The nominal longitudinal impedances both equal 6 MRayl. Normal-incidence power transmission is unity in the model.

Setup

Wedge or couplant

°
Measured from the normal.
m/s
g/cm³

Test material

m/s
m/s
g/cm³
Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Refracted L
0°
Refracted S
0°
Critical 1
30°
Critical 2
—
Normal incidence

An ideal isotropic plane interface does not generate a shear wave at normal incidence.

Refraction at the wedge interfaceAll angles are measured from the surface normal. The lower band marks the kinematic regimes and current incidence.Wedge interfaceFrom normalIncidence / critical bands0°Incident rayL modeS mode
All angles are measured from the surface normal. The lower band marks the kinematic regimes and current incidence.
Wedge L velocity used
3000m/s
Part L velocity used
6000m/s
Part S velocity used
2500m/s
Wedge acoustic impedance
6MRayl
Part acoustic impedance
6MRayl
Normal power reflection
0%
Normal power transmission
100%
Normal one-way interface loss
0dB

The reflection, transmission and loss figures apply to longitudinal waves at normal incidence. Material presets are typical values. Calibrate beam index and angle on a suitable reference block. Equations and references