ASME V Article 4

PMMA wedge below the first critical angle

A 15° PMMA incidence is used on an austenitic 304 stainless test block.

Reading the result. The longitudinal mode refracts to about 33.29°. Both bulk modes are kinematically available in this ideal interface.

Setup

Wedge or couplant

°
Measured from the normal.

Test material

Worked examples

Results update as you edit. Use calibrated measurements.

Inspection readout

SI units
Refracted L
33.293°
Refracted S
17.091°
Critical 1
28.132°
Critical 2
61.72°
L and S kinematically allowed

Mode amplitudes depend on incidence, coupling and elastic properties.

Refraction at the wedge interfaceAll angles are measured from the surface normal. The lower band marks the kinematic regimes and current incidence.Wedge interfaceFrom normalIncidence / critical bands15°Incident rayL modeS mode
All angles are measured from the surface normal. The lower band marks the kinematic regimes and current incidence.
Wedge L velocity used
2730m/s
Part L velocity used
5790m/s
Part S velocity used
3100m/s
Wedge acoustic impedance
3.2214MRayl
Part acoustic impedance
45.915MRayl
Normal power reflection
75.495%
Normal power transmission
24.505%
Normal one-way interface loss
6.1074dB

The reflection, transmission and loss figures apply to longitudinal waves at normal incidence. Material presets are typical values. Calibrate beam index and angle on a suitable reference block. Equations and references