0.5 oz Copper Inner Layer PCB Trace Width & Ampacity Calculator

Check minimum trace width and milliohm resistance for 0.5 oz (17.5 µm) inner copper layers carrying 1 A auxiliary power or actuator loads.

Jump to results

Inputs

Current & thermal budget
Common baseline is 10 °C; power boards often allow 20–30 °C.
Board stackup & trace drop
Applies in IPC-2152 mode to account for copper plane heat spreading.

Results

Estimates
Minimum PCB trace width30.8 mil (0.78 mm)
Trace resistance
66.77 mΩ
Voltage drop
66.8 mV (1.34%)
Copper power loss
66.8 mW
Cross-sectional area
0.0137 mm² (21.2 mil²)
Operating copper temp
35 °C (73.1 A/mm²)
External equivalent
19.3 mil (0.49 mm)
PCB copper cross-section & weight comparison
W = 30.8 mil (0.78 mm)FR-4 Core (Internal Layer)t = 17.5 µm (0.5 oz)Reference Ground Plane (IPC2152) 0.5 oz (internal) 30.8 mil · 0.78 mm 1 oz (internal) 15.4 mil · 0.39 mm 2 oz (internal) 7.7 mil · 0.2 mm 3 oz (internal) 5.1 mil · 0.13 mm
Copper weight & layer comparison
CopperLayerWidth (mil)Width (mm)R (mΩ)Drop (mV)Loss (mW)
0.5 ozexternal19.30.49106.21106.2106.2
0.5 ozinternal30.80.7866.7766.866.8
1 ozexternal9.70.25106.21106.2106.2
1 ozinternal15.40.3966.7766.866.8
2 ozexternal4.80.12106.21106.2106.2
2 ozinternal7.70.266.7766.866.8
3 ozexternal3.20.08106.21106.2106.2
3 ozinternal5.10.1366.7766.866.8

Calculated using IPC2152 at 35 °C copper temperature. Add copper pour or thermal vias if board airflow is restricted.

Avoid undersizing 0.5 oz inner-layer power routes

Most quick-turn 4-layer and 6-layer PCB processes default to 0.5 oz (17.5 µm) copper on internal layers while using 1 oz plated copper on outer layers. Routing a 1 A supply rail on an inner 0.5 oz layer requires double the width of a 1 oz layer for the same temperature rise and resistance.

Check the exact width and milliohm drop here before locking inner-layer power track widths in KiCad or Altium design rules.

Formulas

  • Thickness_0.5oz = 0.689 mil (17.5 µm)
  • R_sheet(0.5 oz, 20 °C) ≈ 0.985 mΩ/square
  • Width_mm = Width_mil × 0.0254

Worked example

Carrying 1 A on an internal 0.5 oz trace at 10 °C rise on a multilayer board requires ~24.8 mil (0.63 mm). Over 50 mm, trace resistance is ~83 mΩ, dropping 83 mV (1.66% of a 5 V rail).

Frequently asked questions

How much current can a 10 mil trace on 0.5 oz inner copper carry?

At 10 °C temperature rise, a 10 mil (0.25 mm) 0.5 oz inner trace typically supports roughly 0.45–0.55 A depending on adjacent plane coupling.

Why are outer layers 1 oz when inner layers are 0.5 oz?

Outer layers start as 0.5 oz base foil and gain additional copper during through-hole barrel electroplating, ending near 1 oz finished thickness.

Is 0.5 oz copper better for controlled-impedance differential pairs?

Yes. Thinner inner copper allows narrower 50 Ω / 90 Ω / 100 Ω impedance-controlled traces with tighter etch tolerance.