Avoid undersizing 0.5 oz inner-layer power routes
Most quick-turn 4-layer and 6-layer PCB processes default to 0.5 oz (17.5 µm) copper on internal layers while using 1 oz plated copper on outer layers. Routing a 1 A supply rail on an inner 0.5 oz layer requires double the width of a 1 oz layer for the same temperature rise and resistance.
Check the exact width and milliohm drop here before locking inner-layer power track widths in KiCad or Altium design rules.
Formulas
Thickness_0.5oz = 0.689 mil (17.5 µm)R_sheet(0.5 oz, 20 °C) ≈ 0.985 mΩ/squareWidth_mm = Width_mil × 0.0254
Worked example
Carrying 1 A on an internal 0.5 oz trace at 10 °C rise on a multilayer board requires ~24.8 mil (0.63 mm). Over 50 mm, trace resistance is ~83 mΩ, dropping 83 mV (1.66% of a 5 V rail).