Size PCB power traces with IPC-2152 thermal awareness
A copper PCB trace behaves as both a resistor and a heat spreader. While legacy IPC-2221 formulas treated internal layers with a rigid 2× width penalty, IPC-2152 finite-element measurements showed that nearby ground planes and FR-4 dielectric thickness dramatically help dissipate heat from both inner and outer traces.
This calculator computes required copper cross-sectional area and trace width in mils and millimeters, then evaluates temperature-corrected copper resistivity at T_ambient + ΔT to report exact milliohm resistance, voltage drop and I²R power loss. Export the comparison table directly as CSV for your PCB design rules.
Formulas
Area (mil²) = [I ÷ (k × ΔT^0.44)]^(1 ÷ 0.725) × plane_modifierWidth (mil) = Area (mil²) ÷ (Copper_oz × 1.378 mil/oz)R_trace (Ω) = ρ_20 × [1 + 0.00393 × (T_op − 20)] × L ÷ A_cross
Worked example
For 3 A on a 1 oz external trace with a 10 °C rise and a 2-layer partial plane (0.82×), IPC-2152 yields roughly 53.7 mil (1.36 mm). Over a 50 mm run at 35 °C copper temperature, trace resistance is ~19.1 mΩ, dropping 57.3 mV and dissipating 172 mW.