3.7V LiPo to 5V 2A Boost Converter Inductor & Ripple Calculator

Size a single-cell LiPo (3.0 V–4.2 V) to 5 V 2 A power-bank boost inductor, checking worst-case peak current at 3.2 V discharged battery voltage.

Jump to results

Inputs

Converter operating point
Ripple & parasitic targets
Typical design range is 20%–40% for CCM operation.

Results

Estimates
Minimum inductance (L)1.8 µH (std: 2.2 µH)
Peak / valley current
3.42 A / 2.52 A
Inductor RMS / ΔI_L
2.98 A rms · ΔI = 0.89 A
Min saturation rating
≥ 4.44 A (1.3× I_peak)
Min output capacitance
17.3 µF (ESR ≤ 14.6 mΩ)
Inductor DCR loss
0.178 W (D = 26%)
Conduction mode
CCM (continuous conduction)
Inductor current triangular ripple waveform (2 switching cycles)
3.42A2.97A2.52At_on (0.43 µs)t_offΔI_L = 0.89 A · D = 26%
Inductance vs. ripple ratio sweep
Ripple RatioInductance (µH)ΔI_L (A)I_peak (A)I_rms (A)
20%2.70.593.272.97
30%1.80.893.422.98
40%1.351.193.562.99
50%1.081.493.713

With a standard 2.2 µH inductor, ripple becomes 0.73 A (I_peak = 3.33 A). Derate ceramic capacitors for DC bias voltage.

Size a LiPo-to-5 V boost inductor for discharged battery worst case

Single-cell LiPo batteries span 4.2 V full down to ~3.0–3.2 V cutoff. While nominal calculations use 3.7 V, peak inductor current reaches its maximum right at low-battery cutoff because lower Vin demands more input current and higher duty cycle to maintain 5 V at 2 A (10 W).

Toggle the 3.2 V low-battery preset to confirm that your inductor’s saturation current (I_sat) and DCR heating stay safe all the way to empty.

Formulas

  • At 3.7 V: D = 26.0%, I_L,avg = 2.97 A, L_min = 1.80 µH
  • At 3.2 V: D = 36.0%, I_L,avg = 3.55 A, I_peak = 4.08 A
  • Choose I_sat from lowest Vin (3.2 V) and L_min from worst ripple

Worked example

At 3.7 V nominal and 600 kHz, minimum inductance is 1.80 µH (standard 2.2 µH) with 3.42 A peak; at 3.2 V low battery, peak current climbs to 4.08 A (requiring I_sat ≥ 5.3 A).

Frequently asked questions

Should I choose a 2.2 µH or 4.7 µH inductor for a 3.7 V to 5 V 2 A boost?

At 600 kHz–1 MHz, 2.2 µH keeps DCR very low (~15–20 mΩ) and maximizes battery efficiency; use 4.7 µH only if switching below 400 kHz.

Why does boost efficiency drop as the LiPo discharges toward 3.2 V?

Higher input current increases I²R losses quadratically across the inductor DCR, battery internal resistance and low-side MOSFET R_DS(on).

What happens if a boost converter’s load shorts to ground?

A standard non-synchronous boost has a direct DC path from Vin through the inductor and diode to Vout; use a boost IC with true load-disconnect or an input fuse.