Size switching converter inductors for controlled ripple and saturation headroom
In both buck and boost DC-DC converters, the inductor sets the peak-to-peak triangle current ripple ΔI_L. Designing around a 20% to 40% ripple ratio keeps the converter comfortably in Continuous Conduction Mode (CCM) under rated load while balancing inductor physical size against output capacitor ripple stress.
Never select an inductor solely by its inductance and average DC current. The core must tolerate I_peak = I_L,avg + ΔI_L/2 with at least 30% saturation margin (I_sat ≥ 1.3 × I_peak) to prevent core collapse during load transients, while RMS current sets I²·DCR copper heating.
Formulas
Buck: D = V_out ÷ V_in; L = V_out × (V_in − V_out) ÷ (V_in × f_sw × ΔI_L)Boost: D = 1 − (V_in ÷ V_out); L = (V_in × D) ÷ (f_sw × ΔI_L)I_rms = √(I_L,avg² + ΔI_L² ÷ 12); P_DCR = I_rms² × DCR
Worked example
Stepping 24 V down to 5 V at 3 A and 300 kHz with 30% ripple (ΔI_L = 0.9 A) requires at least 14.66 µH (next standard value: 15 µH). Peak inductor current is 3.45 A, recommending an inductor with I_sat ≥ 4.5 A and minimum output capacitance around 7.5 µF plus low ESR.