Compare conduction vs. switching heat in 48 V BLDC motor stages
Three-phase BLDC motor inverters typically switch at 20 kHz to stay above audible whine. At 48–52 V bus voltage and 25 A phase current, slow gate resistors (`tr + tf > 100 ns`) can easily make switching loss match or exceed conduction loss.
Compare 20 kHz against 40 kHz PWM using the preset to quantify how gate transition speed and switching frequency trade off against heatsink size.
Formulas
P_cond = I_rms² × R_DS(on)_hot × DutyP_sw = 0.5 × V_bus × I_phase × (t_r + t_f) × f_swTarget T_J ≤ T_J,max − 25 °C
Worked example
At 52 V, 25 A, 50% duty and 20 kHz with 80 ns combined switching time, P_cond = 2.11 W and P_sw = 1.04 W (3.15 W total), reaching T_J = 64.5 °C on a 5 °C/W heatsink.