TO-220 MOSFET Heatsink Thermal Resistance Calculator at 20A

Compute conduction + switching loss, R_θJC/R_θCS/R_θSA temperature stackup and required heatsink °C/W rating for a 20 A TO-220 MOSFET.

Jump to results

Inputs

MOSFET electrical losses
Use RMS over the conduction interval. The switching estimate uses this value as a proxy for transition current.
Silicon MOSFET R_DS(on) typically rises 1.3×–1.6× at 100–125 °C.
Use 100% for a continuously ON load switch.
Set 0 kHz for pure DC static load switching.
Thermal stackup (J → C → S → A)
Silicone pad ~0.5–1.0 °C/W; bare grease ~0.2 °C/W.
No heatsink TO-220 free air is ~60 °C/W.

Results

Estimates
Estimated junction temp (TJ)56.4 °C (+93.6 °C margin)
Total MOSFET loss
2.93 W (2.09 W cond + 0.84 W sw)
Thermal status
Safe (≥ 25 °C margin)
Case / heatsink temp
TC = 53.2 °C · TS = 51.7 °C
Total R_θJA stackup
5.6 °C/W
Hot R_DS(on) used
8.7 mΩ
Max R_θSA for 25 °C margin
27.43 °C/W
Thermal resistance ladder & junction temperature gauge
RθJC 1.1 °C/W RθCS 0.5 °C/W RθSA 4 °C/W 56° Junction (TJ) 53° Case (TC) 52° Heatsink (TS) 40° Ambient (TA)TJ = 56.4 °C · Total loss = 2.93 WTJ,max = 150 °C
Heatsink thermal resistance comparison
Cooling optionR_θSA (°C/W)Est. TJ (°C)Margin to TJ,max25 °C Screen
Sink to ambient · 1.5 °C/W1.549.1100.9 °CPass
Sink to ambient · 3 °C/W353.596.5 °CPass
Sink to ambient · 6 °C/W662.387.7 °CPass
Sink to ambient · 12 °C/W1279.870.2 °CPass
Sink to ambient · 25 °C/W25117.932.1 °CPass
Sink to ambient · 62 °C/W62226.2-76.2 °CHot

Always verify SOA curves, gate-drive rise/fall times under real capacitive load, and airflow orientation against the heatsink datasheet.

Verify TO-220 MOSFET junction temperature and heatsink °C/W at 20 A

A TO-220 MOSFET rated "100 A" on page 1 of its datasheet can rarely dissipate more than 1.5 W without a heatsink. At 20 A RMS and 25 kHz PWM, combined hot conduction loss and 48 V switching overlap easily reach 3–4 W, requiring a properly sized aluminum heatsink and low-impedance thermal pad.

Inspect each node of the thermal ladder (Junction → Case → Sink → Ambient) to see whether your bottleneck is the silicone insulator pad or the heatsink extrusion.

Formulas

  • P_cond = 20² × (0.006 × 1.45) × 0.60 = 2.09 W
  • P_sw = 0.5 × 48 × 20 × 70 ns × 25 kHz = 0.84 W
  • T_J = 40 + 2.93 × (1.1 + 0.5 + 4.0) = 56.4 °C

Worked example

At 20 A, 48 V, 25 kHz and 6 mΩ (1.45× hot), total dissipation is 2.93 W. Through a 4.0 °C/W heatsink plus 0.5 °C/W TIM, T_J sits comfortably at 56.4 °C (+93.6 °C margin).

Frequently asked questions

How much does an insulating Sil-Pad add to R_θCS on a TO-220?

A standard 0.2 mm silicone insulator pad adds ~0.5–1.0 °C/W, whereas thermally conductive grease on a non-isolated tab drops R_θCS to ~0.15–0.25 °C/W.

Why does a clip-on 10 °C/W heatsink run much hotter inside a sealed enclosure?

Published heatsink R_θSA ratings assume unrestricted natural convection at 25 °C ambient; sealed boxes raise local T_A and cut convection airflow by 30%–50%.

What safety margin below T_J,max should I target for industrial reliability?

Derate junction temperature by at least 25–35 °C below T_J,max (e.g., keep T_J ≤ 115–125 °C on a 150 °C MOSFET) to protect solder joints and wire bonds.