Check continuous I²·R_DS(on) heating on 100%-duty DC load switches
Electronic fuses, reverse-polarity protectors and BMS charge/discharge disconnects stay continuously ON (`Duty = 100%`, `f_sw = 0 kHz`). With zero switching loss, steady-state thermal equilibrium depends solely on I² × R_DS(on)_hot and the heatsink path.
Never forget the hot R_DS(on) multiplier: at 100–125 °C junction temperature, a "3.5 mΩ" MOSFET actually conducts at ~5.1 mΩ, adding 45% more watts than naive room-temperature math predicts.
Formulas
P_sw = 0 W (static DC)P_cond = I² × R_DS(on)_25 × k_tempR_θSA_max = ((T_J,max − 25 − T_A) ÷ P_cond) − R_θJC − R_θCS
Worked example
Passing 30 A continuously through a 3.5 mΩ MOSFET (5.08 mΩ hot) generates 4.57 W. Across a 1.0 + 0.4 + 8.0 = 9.4 °C/W stack at 40 °C ambient, T_J climbs to 82.9 °C (+67.1 °C margin).