No-Heatsink Free-Air & PCB Copper Pad MOSFET Thermal Limit Calculator

Find the safe current limit for a bare TO-220 (60 °C/W) or D2PAK/SO-8 PCB copper-pour MOSFET (35 °C/W) without an external heatsink.

Jump to results

Inputs

MOSFET electrical losses
Use RMS over the conduction interval. The switching estimate uses this value as a proxy for transition current.
Silicon MOSFET R_DS(on) typically rises 1.3×–1.6× at 100–125 °C.
Use 100% for a continuously ON load switch.
Set 0 kHz for pure DC static load switching.
Thermal stackup (J → C → S → A)
Silicone pad ~0.5–1.0 °C/W; bare grease ~0.2 °C/W.
No heatsink TO-220 free air is ~60 °C/W.

Results

Estimates
Estimated junction temp (TJ)90.8 °C (+59.2 °C margin)
Total MOSFET loss
0.91 W (0.91 W cond + 0 W sw)
Thermal status
Safe (≥ 25 °C margin)
Case / heatsink temp
TC = 89.4 °C · TS = 89.4 °C
Total R_θJA stackup
61.5 °C/W
Hot R_DS(on) used
25.2 mΩ
Max R_θSA for 25 °C margin
97.71 °C/W
Thermal resistance ladder & junction temperature gauge
RθJC 1.5 °C/W RθCS 0 °C/W RθSA 60 °C/W 91° Junction (TJ) 89° Case (TC) 89° Heatsink (TS) 35° Ambient (TA)TJ = 90.8 °C · Total loss = 0.91 WTJ,max = 150 °C
Heatsink thermal resistance comparison
Cooling optionR_θSA (°C/W)Est. TJ (°C)Margin to TJ,max25 °C Screen
Sink to ambient · 1.5 °C/W1.537.7112.3 °CPass
Sink to ambient · 3 °C/W339.1110.9 °CPass
Sink to ambient · 6 °C/W641.8108.2 °CPass
Sink to ambient · 12 °C/W1247.2102.8 °CPass
Sink to ambient · 25 °C/W255991 °CPass
Sink to ambient · 62 °C/W6292.657.4 °CPass

Always verify SOA curves, gate-drive rise/fall times under real capacitive load, and airflow orientation against the heatsink datasheet.

Determine when a MOSFET can safely skip an external heatsink

Eliminating bulky screw-mounted heatsinks cuts assembly labor and board height, but bare packages have steep junction-to-ambient thermal resistance: roughly 60–62 °C/W for a free-standing TO-220, or 30–45 °C/W for a PowerPAK / D2PAK soldered to 1 in² of 2 oz PCB copper with thermal vias.

At 60 °C/W and 35 °C ambient, even 1.5 W of dissipation drives junction temperature to 125 °C—proving why ultra-low R_DS(on) (<10 mΩ) is essential for heatsinkless designs.

Formulas

  • Bare TO-220 R_θJA ≈ 60–62 °C/W (R_θCS = 0)
  • P_max(free air, 125 °C target) = (125 − 35) ÷ 61.5 ≈ 1.46 W
  • I_max = √(P_max ÷ R_DS(on)_hot)

Worked example

Running 6 A through an 18 mΩ MOSFET (25.2 mΩ hot) dissipates 0.91 W. Free-standing at 61.5 °C/W and 35 °C ambient, T_J reaches 90.8 °C (+59.2 °C margin)—safe without a heatsink.

Frequently asked questions

How much copper pour reduces SMD MOSFET R_θJA?

Expanding from minimum footprint pads (~90 °C/W) to 1 in² (645 mm²) of 2 oz copper stitched to a bottom ground plane typically drops R_θJA into the 30–40 °C/W range.

Is 90 °C case temperature safe to touch on a heatsinkless PCB?

While silicon is happy at 90 °C, 90 °C burns human fingers and can discolor FR-4 over years; keep unguarded surface temperatures below 65–70 °C where practical.

When do thermal vias under a D2PAK / QFN stop helping?

Adding more vias yields diminishing returns past ~12–16 stitched 0.3 mm vias directly under the exposed thermal pad; spreading copper area on the opposite layer matters more after that.