1MHz High-Frequency Buck Converter Inductor & Cap Sizing Calculator

Size ultra-compact 1 MHz–2.2 MHz synchronous buck inductors (1.5–4.7 µH) for 5 V-to-1.8 V and 12 V-to-3.3 V space-constrained PCBs.

Jump to results

Inputs

Converter operating point
Ripple & parasitic targets
Typical design range is 20%–40% for CCM operation.

Results

Estimates
Minimum inductance (L)1.92 µH (std: 2.2 µH)
Peak / valley current
2.3 A / 1.7 A
Inductor RMS / ΔI_L
2.01 A rms · ΔI = 0.6 A
Min saturation rating
≥ 2.99 A (1.3× I_peak)
Min output capacitance
3.7 µF (ESR ≤ 33.3 mΩ)
Inductor DCR loss
0.101 W (D = 36%)
Conduction mode
CCM (continuous conduction)
Inductor current triangular ripple waveform (2 switching cycles)
2.3A2A1.7At_on (0.36 µs)t_offΔI_L = 0.6 A · D = 36%
Inductance vs. ripple ratio sweep
Ripple RatioInductance (µH)ΔI_L (A)I_peak (A)I_rms (A)
20%2.880.42.22
30%1.920.62.32.01
40%1.440.82.42.01
50%1.1512.52.02

With a standard 2.2 µH inductor, ripple becomes 0.52 A (I_peak = 2.26 A). Derate ceramic capacitors for DC bias voltage.

Shrink passives with 1 MHz+ synchronous point-of-load bucks

Modern integrated point-of-load buck ICs switch at 1 MHz to 2.2 MHz so core power rails (1.8 V, 1.2 V, 3.3 V) fit inside tiny 3×3 mm or 4×4 mm molded inductors and pure MLCC ceramic output banks.

At 1 MHz, core AC losses and PCB switch-node ringing rise steeply: keep the high-frequency input capacitor loop razor-short and select an inductor core material specifically rated for MHz switching.

Formulas

  • D = 1.8 ÷ 5.0 = 36.0%
  • L = 1.8 × 3.2 ÷ (5.0 × 1,000,000 × 0.60) = 1.92 µH → std 2.2 µH
  • C_out_min = 0.60 ÷ (8 × 1,000,000 × 0.020) = 3.75 µF

Worked example

Stepping 5 V to 1.8 V at 2 A and 1 MHz requires 1.92 µH (standard 2.2 µH), 2.30 A peak current (I_sat ≥ 2.99 A) and only 3.75 µF ideal output capacitance.

Frequently asked questions

Why should I check inductor self-resonant frequency (SRF) at 1–2.2 MHz?

An inductor’s SRF should sit at least 10× above f_sw (≥20 MHz) so inter-winding capacitance does not bypass high-frequency switching noise directly to Vout.

Does higher switching frequency always improve efficiency?

No—smaller inductance lowers DCR slightly, but gate-drive, switching overlap and core hysteresis losses increase proportionally with frequency.

Why is 5 V to 1.8 V ideal for 1–2.2 MHz operation?

Low input voltage (5 V) keeps CV²f switching losses tiny and keeps minimum on-time comfortably above the buck IC’s 50–80 ns blanking limit.