RL Low-Pass Power Rail Choke Filter & Attenuation Calculator

Calculate cutoff frequency fc, L/R time constant, inductive reactance and attenuation for an RL series choke filter on DC power and sensor rails.

Jump to results

Inputs

Filter topology & components
Frequency evaluation

Results

Estimates
−3 dB Cutoff frequency (fc)15.92 kHz
Time constant (τ)
10 µs
Gain at f_test
-25.52 dB (5.3%)
Phase shift at f_test
-87°
Settling time (3τ / 5τ)
30 µs / 50 µs
Reactance at f_test
188.5 Ω
Total impedance |Z|
188.76 Ω
Bode magnitude plot (0.01·fc to 100·fc)
0 dB -20 dB -40 dB0.01×0.1×fc10×100×fc = 15.92 kHz (−3 dB) · Amber dot: f_test
Frequency response sweep
Frequencyf / fcMagnitude |H|Gain (dB)Phase (°)
159.15 Hz0.01×1-4.34e-4 dB-0.6°
1.59 kHz0.1×0.995-0.04 dB-5.7°
7.96 kHz0.5×0.8944-0.97 dB-26.6°
15.92 kHz1×0.7071-3.01 dB-45°
31.83 kHz2×0.4472-6.99 dB-63.4°
159.15 kHz10×0.0995-20.04 dB-84.3°
1.59 MHz100×0.01-40 dB-89.4°

First-order passive filters roll off at −20 dB/decade (−6 dB/octave). Buffer the output if downstream load impedance is less than 10× R.

Filter switching ripple on high-current rails using an RL choke

When filtering noise on a DC supply rail carrying hundreds of milliamps or several amps, a series resistor wastes power and ruins load regulation. Replacing the resistor with a low-DCR series inductor (choke) feeding the effective load resistance `R = V / I` forms an RL low-pass filter with near-zero DC drop.

Inspect reactance `X_L = 2πfL` and dB attenuation at your switching converter’s ripple frequency (e.g., 300 kHz).

Formulas

  • τ = L ÷ R; f_c = R ÷ (2π × L)
  • X_L = 2π × f_test × L
  • RL Low-Pass |H(f)| = R ÷ √(R² + X_L²)

Worked example

A 100 µH choke into an effective 10 Ω load sets f_c = 15.92 kHz (τ = 10 µs). At a 300 kHz buck ripple frequency, X_L reaches 188.5 Ω, attenuating ripple by −25.5 dB.

Frequently asked questions

How do I estimate effective R for a DC load fed by an RL filter?

Divide the rail voltage by average load current (`R_load ≈ V_rail / I_load`). For example, a 5 V / 0.5 A analog subsystem presents ~10 Ω effective load resistance.

What happens if the choke saturates under DC load current?

Inductance L collapses abruptly, pushing f_c upward by 5×–10× and destroying high-frequency attenuation. Always pick I_sat > 1.3 × I_load_max.

Why add a shunt capacitor after the choke to make an LC filter?

An LC filter rolls off at −40 dB/decade instead of −20 dB/decade, though you must damp its resonant peak with an electrolytic cap’s ESR or a small RC snubber.