Size the power inductor for a 24 V to 5 V 3 A industrial buck rail
Stepping a 24 V industrial PLC or robotics rail down to 5 V at 3 A (15 W) operates at a low 20.8% duty cycle. Because the inductor sees 19 V during the switch on-time, sizing inductance for a 30% ripple ratio (0.90 A peak-to-peak) prevents excessive core loss while keeping the inductor footprint compact.
Select a shielded metal-alloy inductor rated for at least 4.5 A saturation current (`I_sat ≥ 1.3 × I_peak`) and check its DCR loss at 3.01 A RMS.
Formulas
D = 5 ÷ 24 = 20.83%L = 5 × (24 − 5) ÷ (24 × 300,000 × 0.90) = 14.66 µH → std 15 µHI_peak = 3.0 + 0.90 ÷ 2 = 3.45 A
Worked example
At 300 kHz and 30% ripple, minimum inductance is 14.66 µH (standard 15 µH), peak current is 3.45 A, minimum saturation rating is 4.49 A and 35 mΩ DCR dissipates 0.317 W.