Worked example

Clear-water scour at a round column

A single circular 0.95 m column stands in 2.2 m of flow at 2.05 m/s. Footing cover is 2.9 m below the current bed.

Results ↓

Inputs

Assessment
Approach & pier geometry
m
m/s
m
m

Hydraulic readout

Footing cover remains

Local scour: 1.97264 m, Footing cover: 0.927362 m, Froude: 0.441349, Skew factor K₂: 1

Local pier scour section and flow attack angleThe local scour hollow and footing cover are drawn relative to the original bed. The plan sketch rotates the pier to the given angle of attack.LOCAL SCOUR1.9726 mFOOTING COVER0.92736 mFROUDE0.44135SKEW FACTOR K₂1Horseshoe vortex & scour holeWaterScour yₛFootingPier plan · approach flowApproachAxisPierLocal scour / original cover1.9726 m / 2.9 m
  • HEC-18 local pier scour only. Add contraction scour and long-term bed change to evaluate total scour. Use the raw CSU estimate and geometry checks when reviewing the aligned-pier cap.
  • The circular planform is symmetric in every flow direction, so K₂ = 1.

Calculation details

Raw CSU scour depth
1.97264 m
Aligned-pier heuristic cap
2.28 m
Original footing cover
2.9 m
Pier nose factor K₁
1
Bed condition factor K₃
1.1

Interpreting this example

The check isolates local scour. Include contraction and degradation before comparing total scour with the allowable foundation exposure.

τ₀ = ρg Rₕ S₀ · θ = τ₀/[ρ (Gₛ − 1)g d₅₀] · yₛ/y₁ = 2 K₁ K₂ K₃ (a/y₁)⁰·⁶⁵ Fr₁⁰·⁴³

The sediment mode compares applied Shields stress with the Soulsby–Whitehouse critical curve. The pier mode applies HEC-18 Equation 7.1 and the angle and nose-factor rules. The aligned rounded-pier rule of thumb is shown alongside raw CSU scour.

Treat these estimates as local screening results. The pier mode needs a separate evaluation of contraction, degradation, debris, complex foundations and cohesive or rock beds.

Worked examples

Open a case to load its inputs and interpretation.

All cases →

Share worksheet