Worked calculation
- The field scale is 200 ÷ 8 − 1 = 24.
- Horizontal coverage is 6.17 × 24 = 148.08 mm. Vertical coverage is 4.55 × 24 = 109.2 mm.
- The vertical sample pitch is 109.2 ÷ 3000 = 0.0364 mm/px.
How the calculation works
Angle and crop factor
angle = 2 × atan(sensor side ÷ (2 × f)), crop = 43.27 mm ÷ sensor diagonalAngles assume a rectilinear lens at infinity. Multiply the focal length by diagonal crop for 35mm equivalence.
Working distance and sampling
WD = f × (1 + field width ÷ sensor width), mm/px = field size ÷ pixelsThe thin-lens distance is measured from the principal plane. Check the lens drawing before setting the physical mount distance.
Questions and answers
Will a 120 × 120 mm part fit in the 200mm inspection view?
The width fits. The height exceeds the modeled 109.2 mm field, so increase distance, use a wider lens or position the part differently.
Why use separate horizontal and vertical mm per pixel values here?
The nominal active dimensions and output pixel counts can have slightly different ratios. Measuring calibration targets on both axes captures the actual scale.