Worked example · Lighting falloff

92 ft flash guide number with a subject at 4 m

The flash label uses GN 92 ft at ISO 100. Your subject is 4 m away. The continuous-light inputs show a separate 100 fc reference at 2 m.

See the worked calculation

Inputs

Results

Runs on your device

Target illuminance
269.1 lx
Stop loss at target
2 stops
Target illuminance
25 fc
Flash aperture at target
f/7.01
Flash reach at chosen aperture
3.51 m
Adjusted guide number
92 ft
Inverse-square falloff
Illuminance from 1,076.39 lux at 2 m to 269.1 lux at 4 mREFERENCETARGET1,076.39 lx · 2 m269.1 lx · 4 m
The curve models the same source, beam and setting at different distances. Reference and target measurements are marked.

Worked calculation

  1. GN 92 ft × 0.3048 = 28.0416 m. At ISO 100 and full power divide by 4 m for f/7.01.
  2. At the chosen f/8 reach setting, 28.0416 ÷ 8 = 3.5052 m.
  3. Independently, 100 fc at 2 m becomes 25 fc at 4 m, equivalent to about 269.10 lx.

How the calculation works

Continuous light

E₂ = E₁ × (d₁ ÷ d₂)², stop loss = 2 × log₂(d₂ ÷ d₁)

Use matching units for both distances and retain the same beam configuration. One foot-candle is about 10.764 lux.

Direct flash

GN adjusted = GN₁₀₀ × √(ISO ÷ 100 × power fraction), N = GN adjusted ÷ distance

Convert distance to the guide-number unit before dividing. Use the manufacturer’s GN at your flash head zoom.

Questions and answers

Is the 25 fc reading used to calculate the flash aperture?

The flash estimate uses GN, distance, ISO and power. The continuous-light calculation is a separate result.

What happens if I divide GN 92 directly by the 4 m subject distance?