Worked example · Lighting falloff

GN 36 flash at quarter power and ISO 400

A flash has a full-power ISO 100 rating of GN 36 m. Set power to 25%, ISO to 400 and subject distance to 6 m.

See the worked calculation

Inputs

Results

Runs on your device

Target illuminance
888.89 lx
Stop loss at target
3.17 stops
Target illuminance
82.58 fc
Flash aperture at target
f/6
Flash reach at chosen aperture
4.5 m
Adjusted guide number
36 m
Inverse-square falloff
Illuminance from 8,000 lux at 2 m to 888.89 lux at 6 mREFERENCETARGET8,000 lx · 2 m888.89 lx · 6 m
The curve models the same source, beam and setting at different distances. Reference and target measurements are marked.

Worked calculation

  1. Quarter output multiplies guide number by √0.25 = 0.5.
  2. ISO 400 multiplies it by √4 = 2, bringing the adjusted guide number back to 36 m.
  3. At 6 m, use f/6 in the ideal model. If you choose f/8, modeled reach is 4.5 m.

How the calculation works

Continuous light

E₂ = E₁ × (d₁ ÷ d₂)², stop loss = 2 × log₂(d₂ ÷ d₁)

Use matching units for both distances and retain the same beam configuration. One foot-candle is about 10.764 lux.

Direct flash

GN adjusted = GN₁₀₀ × √(ISO ÷ 100 × power fraction), N = GN adjusted ÷ distance

Convert distance to the guide-number unit before dividing. Use the manufacturer’s GN at your flash head zoom.

Questions and answers

What if I leave this GN 36 flash at ISO 100 and quarter power?

The adjusted GN would be 18 m. Divide by 6 m to get an aperture near f/3.

How do I enter one-eighth power in the flash calculator?

Enter 12.5 in Flash output (%). The guide number scales by the square root of that power fraction.