Worked example · ND filter exposure

ND100000 from 1/500 s in bright daylight

A scene meters at 1/500 s before the filter. Fit a literal ND100000 filter for an extreme digital long exposure.

See the worked calculation

Inputs

Seconds or a fraction such as 1/125.

Results

Runs on your device

Filtered shutter
3 min 20 s
Reciprocity-adjusted shutter
3 min 20 s
Filter strength
16.6096 stops
Light transmitted
0.001 %
Exposure multiplier
100,000 ×
Optical density
5
Exposure ladder
From 1/500 s to 3 min 20 s over 16.61 stops048121616.611/500 s unfiltered3 min 20 s filteredFILTER STOPS
Each step doubles exposure time. The last tick represents the selected filter, including fractional stops.

Worked calculation

  1. Multiply 1/500 by 100000 to get 200 s, or 3 minutes 20 seconds.
  2. log₂(100000) ≈ 16.61 stops. Its optical density is 5.0.
  3. 100 ÷ 100000 = 0.001% nominal transmission.

How the calculation works

Apply the ND filter

t = t₀ × factor, factor = 2^stops = 10^density

A literal ND1000 factor gives 9.97 stops. An exact 10-stop filter multiplies time by 1024.

Correct film reciprocity

t corrected = t^P for t > 1 s

Apply the film exponent after the filter conversion. The ILFORD model uses the metered time directly at or below one second.

Questions and answers

Do I need bulb or time mode for the 200-second exposure?

Use a mode that supports the calculated time. On cameras capped at shorter timed exposures, use bulb mode or a compatible timer.

How do I focus through an ND100000 filter?

Compose and focus before fitting it if the camera cannot see enough light through the filter. Lock focus before reattaching the filter.