Polymer melt residence time calculator

Estimate average barrel hold-up from shot size, swept capacity, and cycle time, then screen against a resin ceiling.

Edit inputs ↓

Inputs

cm³
cm³
×
2.0–2.5 is a starting point. Use machine data if available.
s
min
Residence
2.13min
Barrel cycles
4.4
Melt inventory
572cm³
Time margin
3.87min

Barrel inventory and shot withdrawal

Live schematic
HEATED BARREL2.2× RATEDHold-up 4.4 cyclesShot 130 cm³

Within residence ceiling

0%100% ceiling125%+

The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.

Calculation details
Shot through barrel130 cm³
Rated barrel capacity260 cm³
Inventory multiplier2.2×
Cycle time29 s
Thermal ceiling6 min
Ceiling used35.4%

Model and assumptions

V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.

Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.