PC optical part on a slow cycle

A long cycle and small optical shot leave material in the barrel for many shots.

Edit inputs ↓

Inputs

cm³
cm³
×
2.0–2.5 is a starting point. Use machine data if available.
s
min
Review calculations ↑
Residence
7.29min
Barrel cycles
8.41
Melt inventory
572cm³
Time margin
-1.29min

Barrel inventory and shot withdrawal

Live schematic
HEATED BARREL2.2× RATEDHold-up 8.41 cyclesShot 68 cm³

Residence ceiling exceeded

0%100% ceiling125%+

The threshold applies to the estimated average residence time. Stagnant melt can stay in the barrel longer.

Calculation details
Shot through barrel68 cm³
Rated barrel capacity260 cm³
Inventory multiplier2.2×
Cycle time52 s
Thermal ceiling6 min
Ceiling used121.5%

Working through the example

The estimated mean exceeds the 6-minute PC screening ceiling. Material in dead spots can stay longer.

V_inventory = K_inv × V_rated. Cycles in barrel = V_inventory/V_shot. t_res (min) = cycles × t_cycle (s)/60.

Use the average running cycle and the melt volume actually discharged per cycle. The 2.0–2.5 inventory multiplier and resin ceilings are screening inputs. Screw design, idle periods, melt temperature and material held in dead spots can change the residence-time distribution.

Methodology and sources