Clamp force 43.66 metric t
Projected area 120 cm²
Press use 85.6 %
Clamp reserve 7.33 metric t
Projected area at the parting plane Live schematic
4 × CAVITIES 31 MPa Area 120 cm² Runner 8 cm²
Within press rating
0% 100% rating 125%+
Includes the entered safety factor. The rating boundary is 100% utilization.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Required clamp force 428.16 kN Required clamp force 48.13 US tons Required clamp force 43.66 metric t Installed press rating 50.99 metric t Cavity pressure 31.03 MPa Reserve of installed rating 14.4%
Model and assumptions
A_proj = N × A_part + A_runner. F_required (kN) = 0.1 × A_proj (cm²) × P_cavity (MPa) × SF.
Use the silhouette in the clamp direction, including the projected feed system. Enter mean cavity pressure at the limiting fill or packing condition. The pressure tiers are starting estimates. Use a measured or simulated cavity pressure for press selection when available. The utilization boundary compares the calculated force with the entered rating.
Methodology and sources
F = (N × Aₚ + Aᵣ) × P × SF
Inputs Cavities 4 Projected area per part 28 cm² Projected runner area 8 cm² Cavity pressure tier ABS / PS · medium Cavity pressure 31.02641 MPa Clamp safety factor 1.15 × Press clamp rating 50.98581 metric t
Results Clamp force 43.66 metric t Projected area 120 cm² Press use 85.6% Clamp reserve 7.33 metric t Required clamp force 428.16 kN Required clamp force 48.13 US tons Required clamp force 43.66 metric t Installed press rating 50.99 metric t Cavity pressure 31.03 MPa Reserve of installed rating 14.4%
Within press rating. Includes the entered safety factor. The rating boundary is 100% utilization.
4 × CAVITIES 31 MPa Area 120 cm² Runner 8 cm²
Use the silhouette in the clamp direction, including the projected feed system. Enter mean cavity pressure at the limiting fill or packing condition. The pressure tiers are starting estimates. Use a measured or simulated cavity pressure for press selection when available. The utilization boundary compares the calculated force with the entered rating.