Pressure-sensor plaque at the clamp boundary

A measured 40 MPa cavity pressure replaces the material preset for one plaque.

Edit inputs ↓

Inputs

cm²
cm²
Total for one shot, including the projected feed system.
MPa
×
Range 1.10–1.25.
metric t
Review calculations ↑
Clamp force
24.47metric t
Projected area
50cm²
Press use
100%
Clamp reserve
0metric t

Projected area at the parting plane

Live schematic
1 × CAVITIES40 MPaArea 50 cm²Runner 0 cm²

Within press rating

0%100% rating125%+

Includes the entered safety factor. The rating boundary is 100% utilization.

Calculation details
Required clamp force240 kN
Required clamp force26.98 US tons
Required clamp force24.47 metric t
Installed press rating24.47 metric t
Cavity pressure40 MPa
Reserve of installed rating0%

Working through the example

The estimate is exactly 240 kN. The press meets the entered threshold with zero remaining reserve.

A_proj = N × A_part + A_runner. F_required (kN) = 0.1 × A_proj (cm²) × P_cavity (MPa) × SF.

Use the silhouette in the clamp direction, including the projected feed system. Enter mean cavity pressure at the limiting fill or packing condition. The pressure tiers are starting estimates. Use a measured or simulated cavity pressure for press selection when available. The utilization boundary compares the calculated force with the entered rating.

Methodology and sources