PC bezel using part-basis shrinkage

The drawing and resin data use shrink allowance relative to nominal part size.

Edit inputs ↓

Inputs

mm
mm
%
%
pp
Percentage points added to and subtracted from each nominal shrinkage.
mm
mm
Review calculations ↑
Steel flow
96.576mm
Steel cross
66.396mm
Worst error
0.0752mm
Shrink delta
0pp

Steel and molded-part dimension overlay

Live schematic
STEEL ENVELOPEMOLDED OUTLINEFlow 96.576 mmCross 66.396 mm

Within part tolerance

0%100% tolerance125%+

Compares the largest absolute error from the two worst-case bands. Directional shrink difference indicates warpage tendency.

Calculation details
Selected conventionPart basis · Lₚ × (1 + S)
Flow molded minimum95.9249 mm
Flow molded maximum96.0752 mm
Cross molded minimum65.9428 mm
Cross molded maximum66.0573 mm
Part tolerance remaining0.0448 mm
Directional shrinkNo difference entered

Working through the example

Multiply nominal size by 1.006 for steel. For the molded extremes, divide each steel limit by its associated shrink factor.

Mold basis S = (L_cav−L_part)/L_cav. Part basis S = (L_cav−L_part)/L_part. Use the same basis for the steel calculation and its inverse.

Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.

Methodology and sources