Steel flow 100.4016 mm
Steel cross 60.5449 mm
Worst error 0.1253 mm
Shrink delta 0.5 pp
Steel and molded-part dimension overlay Live schematic
STEEL ENVELOPE MOLDED OUTLINE Flow 100.402 mm Cross 60.545 mm
Within part tolerance
0% 100% tolerance 125%+
Compares the largest absolute error from the two worst-case bands. Directional shrink difference indicates warpage tendency.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Selected convention Mold basis · Lₚ ÷ (1 − S) Flow molded minimum 99.8747 mm Flow molded maximum 100.1253 mm Cross molded minimum 59.9147 mm Cross molded maximum 60.0853 mm Part tolerance remaining 0.0247 mm Directional shrink Cross-flow shrinks more
Model and assumptions
Mold basis S = (L_cav−L_part)/L_cav. Part basis S = (L_cav−L_part)/L_part. Use the same basis for the steel calculation and its inverse.
Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.
Methodology and sources
L_cav = L_part ÷ (1 − S) or L_part × (1 + S)
Inputs Nominal size in flow 100 mm Nominal size in cross-flow 60 mm Directional shrinkage preset PA66-GF30 · 0.4% / 0.9% Flow shrinkage 0.4 % Cross-flow shrinkage 0.9 % Shrinkage convention Mold basis · divide by (1 − S) Shrinkage process spread ± 0.1 pp Steel machining tolerance ± 0.025 mm Target part tolerance ± 0.15 mm
Results Steel flow 100.4016 mm Steel cross 60.5449 mm Worst error 0.1253 mm Shrink delta 0.5 pp Selected convention Mold basis · Lₚ ÷ (1 − S) Flow molded minimum 99.8747 mm Flow molded maximum 100.1253 mm Cross molded minimum 59.9147 mm Cross molded maximum 60.0853 mm Part tolerance remaining 0.0247 mm Directional shrink Cross-flow shrinks more
Within part tolerance. Compares the largest absolute error from the two worst-case bands. Directional shrink difference indicates warpage tendency.
STEEL ENVELOPE MOLDED OUTLINE Flow 100.402 mm Cross 60.545 mm
Apply the shrinkage spread in percentage points and the steel tolerance as an absolute ± dimension. The low end uses the smallest steel and greatest shrink. The high end uses the largest steel and least shrink. Compare the greatest deviation from either nominal dimension with the part tolerance. Resin presets illustrate directional inputs. Confirm values for the actual grade, flow direction, processing and conditioning.