PMMA lens with zero cushion for comparison

This geometric comparison isolates the stroke needed to meter two optical lenses.

Edit inputs ↓

Inputs

g
g
g/cm³
g/cm³
Use melt density at your processing condition.
mm
mm
mm
Review calculations ↑
Shot weight
89g
Melt volume
88.12cm³
Dose stroke
109.57mm
Barrel use
64.5%

Screw stroke and melt cushion

Live schematic
SCREW Ø 32 mmMAX 170 mmDose 109.57 mmCushion 0 mm

Within 20–80% window

<20%20–80%>80%

Below 20% raises residence-time risk. Above 80% can restrict consistent plasticizing. The cushion also has to fit.

Calculation details
Rated swept volume136.72 cm³
Equivalent solid volume75.42 cm³
Cushion volume0 cm³
Dose plus cushion109.57 mm
Stroke remaining60.43 mm
Melt density1.01 g/cm³

Working through the example

A zero entered cushion makes total stroke equal dosing stroke. Confirm the production cushion separately on the press.

m_shot = N × m_part + m_runner. V_melt = m_shot/ρ_melt. S_dose = 1000V_melt/(πD²/4) with cm³ and mm.

The barrel rating is geometric swept volume. Utilization counts the dose only, with 20–80% inclusive. Add the target cushion separately for the travel check. The solid-density result gives an equivalent room-temperature volume. Material and machine limits can narrow the screening window.