Small press with a cushion conflict

A 36 mm screw meters a two-part shot with a large cushion reserved at the end.

Edit inputs ↓

Inputs

g
g
g/cm³
g/cm³
Use melt density at your processing condition.
mm
mm
mm
Review calculations ↑
Shot weight
54g
Melt volume
59.34cm³
Dose stroke
58.3mm
Barrel use
77.7%

Screw stroke and melt cushion

Live schematic
SCREW Ø 36 mmMAX 75 mmDose 58.3 mmCushion 18 mm

Dose plus cushion exceeds stroke

<20%20–80%>80%

Below 20% raises residence-time risk. Above 80% can restrict consistent plasticizing. The cushion also has to fit.

Calculation details
Rated swept volume76.34 cm³
Equivalent solid volume51.43 cm³
Cushion volume18.32 cm³
Dose plus cushion76.3 mm
Stroke remaining-1.3 mm
Melt density0.91 g/cm³

Working through the example

The dose alone lies in the target utilization window. Adding the 18 mm cushion pushes the total beyond the 75 mm stroke.

m_shot = N × m_part + m_runner. V_melt = m_shot/ρ_melt. S_dose = 1000V_melt/(πD²/4) with cm³ and mm.

The barrel rating is geometric swept volume. Utilization counts the dose only, with 20–80% inclusive. Add the target cushion separately for the travel check. The solid-density result gives an equivalent room-temperature volume. Material and machine limits can narrow the screening window.