Wall shear 137,255 s⁻¹
Apparent shear 83,333 s⁻¹
Pressure drop 1.451 MPa
Wall viscosity 1.586 Pa·s
Velocity profile through the gate or runner Live schematic
FLOW PROFILE SLIT SECTION Land 2 mm 14 × 0.6 mm Q 70 cm³/s ΔP 1.451 MPa
Resin shear limit exceeded
0% 100% limit 125%+
The wide-slit model assumes negligible sidewall effects. A shear-limit check screens for possible splay, burn marks and degradation.
Share link Reset defaults JSON CSV SVG PNG (2×) Print A4
Calculation details
Volume flow through one channel 70 cm³/s Rabinowitsch factor 1.647× Resin wall-shear limit 40,000 s⁻¹ Shear rate below limit -97,255 s⁻¹ Shear limit used 343.1% Slit width to gap 23.33×
Working through the example
The squared gate gap dominates the slit estimate. Corrected wall shear exceeds the 40,000 s⁻¹ limit.
Round γ_app = 32Q/(πD³), correction (3n+1)/(4n). Slit γ_app = 6Q/(wh²), correction (2n+1)/(3n). η = Kγ_w^(n−1).
Use flow per gate or runner and consistent temperature-specific K and n. The pressure drop is wall stress times 4L/D for the round channel or 2L/h for the wide slit. This assumes isothermal, fully developed, no-slip flow and omits entry loss. Aspect ratios below 5:1 require a finite-width check. The supported power-law index is 0.1 < n ≤ 1.
Methodology and sources
τ_w = Kγ_wⁿ · ΔP = τ_w × (4L/D or 2L/h)
Inputs Channel geometry Rectangular edge / tab gate Gate width 14 mm Gate gap 0.6 mm Channel land length 2 mm Fill volume through one channel 35 cm³ Fill time 0.5 s Power-law consistency K 3,900 Pa·sⁿ Power-law flow index n 0.34 Resin wall-shear limit 40,000 s⁻¹
Results Wall shear 137,255 s⁻¹ Apparent shear 83,333 s⁻¹ Pressure drop 1.451 MPa Wall viscosity 1.586 Pa·s Volume flow through one channel 70 cm³/s Rabinowitsch factor 1.647× Resin wall-shear limit 40,000 s⁻¹ Shear rate below limit -97,255 s⁻¹ Shear limit used 343.1% Slit width to gap 23.33×
Resin shear limit exceeded. The wide-slit model assumes negligible sidewall effects. A shear-limit check screens for possible splay, burn marks and degradation.
FLOW PROFILE SLIT SECTION Land 2 mm 14 × 0.6 mm Q 70 cm³/s ΔP 1.451 MPa
Use flow per gate or runner and consistent temperature-specific K and n. The pressure drop is wall stress times 4L/D for the round channel or 2L/h for the wide slit. This assumes isothermal, fully developed, no-slip flow and omits entry loss. Aspect ratios below 5:1 require a finite-width check. The supported power-law index is 0.1 < n ≤ 1.