Wide PP tab gate wall shear

A wide, short land feeds a PP part at a moderate volume rate.

Edit inputs ↓

Inputs

Channel geometry
mm
mm
mm
Fill and resin
cm³
s
Pa·sⁿ
Use a fitted 0.1 < n ≤ 1 for the relevant shear range.
s⁻¹
Review calculations ↑
Wall shear
6,854s⁻¹
Apparent shear
4,693s⁻¹
Pressure drop
0.98MPa
Wall viscosity
35.753Pa·s

Velocity profile through the gate or runner

Live schematic
FLOW PROFILESLIT SECTIONLand 2.5 mm10 × 1.25 mmQ 12.22 cm³/sΔP 0.98 MPa

Within resin shear limit

0%100% limit125%+

The wide-slit model assumes negligible sidewall effects. A shear-limit check screens for possible splay, burn marks and degradation.

Calculation details
Volume flow through one channel12.22 cm³/s
Rabinowitsch factor1.46×
Resin wall-shear limit22,000 s⁻¹
Shear rate below limit15,146 s⁻¹
Shear limit used31.2%
Slit width to gap8×

Working through the example

Use the single gate volume and fill time. The slit correction increases apparent wall shear before the limit check.

Round γ_app = 32Q/(πD³), correction (3n+1)/(4n). Slit γ_app = 6Q/(wh²), correction (2n+1)/(3n). η = Kγ_w^(n−1).

Use flow per gate or runner and consistent temperature-specific K and n. The pressure drop is wall stress times 4L/D for the round channel or 2L/h for the wide slit. This assumes isothermal, fully developed, no-slip flow and omits entry loss. Aspect ratios below 5:1 require a finite-width check. The supported power-law index is 0.1 < n ≤ 1.