Calculation Methodology
Flow references, pressure conventions, and model limits for PneumaticAirLab’s compressed-air and vacuum tools.
One stored value, two unit systems
Each calculation stores inputs in canonical units. Switching the display leaves the stored numerical values intact. The formulas use pascals, kelvin, meters, cubic meters, and seconds. Power is stored in kW.
- SCFM and scf
- Dry gas at 60 °F and 101.325 kPa absolute.
- NL/min, Nm³/min and NL
- Dry gas at 0 °C and 101.325 kPa absolute.
- ACFM and suction L/min
- Actual volumetric flow in the evacuated system.
- Gauge and absolute pressure
- Add 101.325 kPa (14.696 psi) to gauge pressure to obtain absolute pressure. Vacuum is the positive pressure difference below that reference.
On these bases, 1 SCFM is about 26.791 NL/min. Confirm the reference temperature, pressure, and moisture basis before using OEM flow data. CAGI and ISO 1217 data often use 20 °C and 1 bar dry. Normalize FAD and flow test data to the selected basis first.
Models by calculator
- Cylinder force & air useCheck push and pull force, size a bore for your load, and estimate how much free air a double-acting cylinder uses.
- Receiver tank sizingSize storage for a demand surge and check the pump-up, blow-down, and estimated starts per hour of an installed receiver.
- Header pressure dropEstimate friction loss and actual line velocity for a straight compressed-air header with fittings.
- Leak flow & costTurn an orifice size and header pressure into free-air loss, wasted compressor power, and annual electricity cost.
- Valve Cv & choked flowSize Cv from target gas flow or predict capacity from an existing Cv. Compare the air-orifice screen with the valve’s ISA choking point.
- Compressor power & savingsCompare annual energy for three load levels, estimate VFD and pressure changes, and calculate simple payback.
- Dew point & condensateFollow water through intake, aftercooler, and dryer. Compare pressure dew point, atmospheric dew point, and drain volume.
- Vacuum cup liftingEstimate holding force, working load, safety factor, and evacuation time for round and oval vacuum cups.
Engineering and safety references
Engineering estimates for preliminary sizing. Follow applicable ASME pressure-vessel codes and local rules. Use lockout/tagout and release stored energy before service. Verify all OEM pressure, vacuum, and load ratings for the actual equipment.
- CAGI reference conditions and glossary
- ISO 1217 compressor acceptance tests
- ISO 6358-1 pneumatic component flow testing
- ISO 8573-1 compressed air purity classes
- Emerson Fisher control valve handbook, chapter 5
- U.S. DOE compressed air sourcebook
- ASME Boiler and Pressure Vessel Code
- OSHA air receivers, 29 CFR 1910.169
- OSHA control of hazardous energy, 29 CFR 1910.147