Calculation Methodology

Flow references, pressure conventions, and model limits for PneumaticAirLab’s compressed-air and vacuum tools.

One stored value, two unit systems

Each calculation stores inputs in canonical units. Switching the display leaves the stored numerical values intact. The formulas use pascals, kelvin, meters, cubic meters, and seconds. Power is stored in kW.

SCFM and scf
Dry gas at 60 °F and 101.325 kPa absolute.
NL/min, Nm³/min and NL
Dry gas at 0 °C and 101.325 kPa absolute.
ACFM and suction L/min
Actual volumetric flow in the evacuated system.
Gauge and absolute pressure
Add 101.325 kPa (14.696 psi) to gauge pressure to obtain absolute pressure. Vacuum is the positive pressure difference below that reference.

On these bases, 1 SCFM is about 26.791 NL/min. Confirm the reference temperature, pressure, and moisture basis before using OEM flow data. CAGI and ISO 1217 data often use 20 °C and 1 bar dry. Normalize FAD and flow test data to the selected basis first.

Models by calculator

Engineering and safety references

Engineering estimates for preliminary sizing. Follow applicable ASME pressure-vessel codes and local rules. Use lockout/tagout and release stored energy before service. Verify all OEM pressure, vacuum, and load ratings for the actual equipment.