Worked example

Baking Soda for a 350-Gallon Spa, 65 to 85 ppm TA

The measured pH starts at 7.4 and the chosen TA target is 85 ppm. Weigh the product and test both values after mixing because the alkalinity adjustment can also move pH.

Jump to results

Example readings

Spa water and dose
US gal
ppm
ppm
Heat-up
kW
°F
°F
Standby cost
W
W
hr/day
USD/kWh

Results

Estimate

Dry product estimate
1.57 oz wt
Approximate US teaspoons
9.81 tsp
Ideal heat-up time
11.98 hr
Ideal heat rate
3.5 °F/hr
Covered standby per month
22.03 USD
Uncovered standby per month
45.36 USD
Monthly cover cost difference
23.33 USD
Measured product mass
44.48 g
Spa heat-up estimate
WATER TEMPERATURE60 °F102 °FStart11.98 hr

Export & share

Worked calculation

  1. Using baking soda / sodium bicarbonate, the buffer calculation gives 0.39965 mmol/L active product and 44.481 g for the spa. The modeled result is pH 7.51 and 85 ppm alkalinity.
  2. 60 °F to 102 °F at 3 kW delivered. Heating 1,325 L by 23.33°C takes 11.98 hours ideally.
  3. (350 W − 170 W) ÷ 1,000 × 24 hr/day × 30 × $0.18/kWh = $23.33 per month.
  • Spoon estimates use 4.93 mL per US teaspoon and an assumed or entered bulk density. Measure small dry doses with a chemical-only scale and liquids with a graduated measure. Use a product labeled for spas.
  • Use a spa test kit and follow the product label. Keep bathers out during treatment and retest before use. CDC advises against CYA and stabilized chlorine in hot tubs. Maintain water at or below 104°F (40°C).
  • Heat-up time assumes no environmental loss. Standby compares average electrical watts you enter across 30 days, so the cost excludes gas and the initial warm-up.

Common questions

Can aerating the 350-gallon spa substitute for baking soda?

Aeration mainly removes dissolved carbon dioxide and can increase pH. Sodium bicarbonate adds alkalinity directly.

How can I verify a 20 ppm TA rise with a drop-count test?

Use the sample volume and drop factor on your kit. If the resolution is 10 ppm per drop, about two additional drops would correspond to 20 ppm.

Method and safety references