Aquarium, reef & pond calculators
Measure twice.
Fill once.
Work out tank weight, reef doses, sump reserve and more before you change your setup. Then verify the numbers in your own water.
Runs in your browser No sign-in
Choose a calculator
Enter your measurements and see the result as you edit.
Tank volume & floor load
Water volume, glass safety factor and the weight your floor will carry.
Reef dosing
Two-part chemistry, measured consumption and split dosing schedules.
Salinity & salt mix
Temperature-aware SG, conductivity, batch salt and water changes.
Heater & chiller
Cold-night heater watts and summer chiller capacity from a heat balance.
Sump & overflow
Return flow, drain-down freeboard and freshwater top-off runtime.
Planted CO₂ & EI dosing
Carbon dioxide from pH and KH, plus dry macro fertilizer by weight.
Lighting & PAR
PAR at the substrate, from surface readings and water clarity.
Koi pond sizing
Pond gallons, EPDM sheet size, waterfall flow and UV planning.
Worked examples
Start with a real setup. Change a measurement to fit yours.
Tank volume & floor load7 examples
- 75-Gallon Aquarium Filled Weight & Floor Load
A standard 48-inch tank on a 49 × 19 in stand.
- 120-Gallon Rimless Aquarium Glass Thickness & Safety Factor
A 19 mm pane screened at a 22.5 in water line.
- 40-Gallon Breeder Aquarium Weight on a Stand
An 18-inch-wide breeder with a known empty tank weight.
- How Much Water Is in a Half-Full 55-Gallon Tank?
A shallow fill for a paludarium or temporary holding setup.
- 46-Gallon Bowfront Aquarium Volume from Chord and Bow
Measure the short straight width and the extra bow separately.
- 30-Inch Cylinder Aquarium Water Volume & Filled Weight
A round column with a measured inside diameter.
- 24-Inch Cube Reef Net Volume With Rock and Sump
A cube’s usable gallons with rock displacement and a running sump.
Reef dosing7 examples
- 50-Gallon Reef Alkalinity from 7.5 to 8.5 dKH with Baking Soda
A 1 dKH correction with sodium bicarbonate stock.
- 90-Gallon Reef Soda Ash Dose for a 0.8 dKH Rise
How a two-equivalent soda ash dose changes the required grams.
- 40-Gallon Reef Anhydrous Calcium Chloride Dose
A 30 ppm calcium correction with the anhydrous salt.
- 120-Gallon Reef Calcium Chloride Dihydrate Dose
Hydrated calcium salt, corrected for its water of crystallization.
- 65-Gallon Reef Magnesium Chloride and Sulfate Dose
Divide a 50 ppm rise between chloride and sulfate sources.
- 75-Gallon Reef Daily Alkalinity Consumption & Auto-Doser Schedule
Calculate a maintenance schedule from two no-dose tests.
- 20-Gallon Nano Reef Magnesium Rise of 50 ppm Over Two Days
A small system with a multi-day magnesium correction.
Salinity & salt mix7 examples
- Mix 20 Gallons of Saltwater at 35 ppt and About 1.026 SG
Weigh out a 20-gallon marine batch at 35 ppt.
- Convert 1.020 Specific Gravity to ppt at 77 °F
A low marine SG reading converted with the sample temperature.
- 53 mS/cm Conductivity to Reef Salinity at 25 °C
A conductivity probe reading near natural seawater.
- 1.028 SG Reef Salinity After a 20% Water Change
How much a routine change can move an elevated SG reading.
- Raise Reef Salinity from 32 to 35 ppt with Water Changes
Solve the mixing equation before choosing a change size.
- Lower 37 ppt to 35 ppt with a Freshwater Dilution Estimate
Calculate the volume-weighted dilution needed for a 2 ppt change.
- 5-Gallon Saltwater Bucket at 34 ppt: Grams and Cups
A small batch scaled to a measured salt brand and cup.
Heater & chiller6 examples
- 90-Gallon Reef Heater Wattage for a 15 °F Rise
An open reef on a cold night with lights off.
- 20-Gallon Lidded Acrylic Aquarium Heater for a 10 °F Rise
A small covered tank with 6 mm acrylic walls.
- 125-Gallon Reef Summer Chiller BTU/hr and HP
A hot-room cooling load with 300 W of reef lighting.
- 55-Gallon Aquarium Heater Capacity for a 58 °F Room
Size the total load before choosing one or two heaters.
- 40-Gallon Breeder Heater Load with an Open Top or Lid
Separate surface and evaporation effects for the same tank.
- 180-Gallon Acrylic Aquarium Chiller with Pump Heat
Equipment heat still matters through thick acrylic walls.
Sump & overflow6 examples
- 40-Gallon Breeder Sump Power-Outage Flood Margin
The water that reaches a breeder sump when the pump stops.
- 1-Inch Aquarium Overflow Drain GPH at 2 Inches of Head
An orifice estimate for one nominal 1-inch pipe.
- 75-Gallon Aquarium Return Pump at 6× Turnover
Use flow at the installed head to compute actual turnover.
- Deep Return Nozzle Siphon and Sump Overflow Risk
A deep nozzle can keep siphoning after the weir stops.
- 10-Gallon ATO Reservoir Runtime for a Reef Tank
Tank top-off runtime from measured warm-weather evaporation.
- 120-Gallon Reef Dual Drains with One Blocked
Compare dual-path and single-path flow when a drain blocks.
Planted CO₂ & EI dosing6 examples
- Planted Tank pH 6.6 and KH 4: CO₂ ppm and EI Dosing
Read the heatmap around the 30 ppm boundary.
- 20-Gallon Planted Tank EI Potassium Nitrate Grams
Convert nitrate ppm to dry KNO₃ per dose and per week.
- 29-Gallon Planted Tank KH₂PO₄ for 1 ppm Phosphate
Use the phosphate mass fraction of KH₂PO₄.
- 55-Gallon Planted Tank Potassium Sulfate Top-Up
Subtract potassium already supplied by nitrate and phosphate.
- Shrimp Tank pH 6.8 and KH 2: CO₂ Estimate
A low estimated CO₂ reading in softer water.
- 4 dKH and pH 6.8: Green Drop-Checker Reference CO₂
The 4 dKH reference illustrates the green planning band.
Lighting & PAR5 examples
- 24-Inch Reef Tank: 450 Surface PAR to Sandbed PAR
Trace 450 surface PAR through a 24-inch reef column.
- 18-Inch Clear Reef: 300 PAR at the Underwater Surface
Start from an immersion-corrected underwater surface reading.
- 16-Inch Tinted Planted Aquarium PAR at the Substrate
See how tinted water changes the light a carpet receives.
- 12-Inch Shallow Reef PAR Loss through a Glass Lid
Keep glass loss and water-column loss separate.
- Calibrate Aquarium PAR Attenuation from Two Readings
Fit the curve with measured PAR at two depths.
Koi pond sizing6 examples
- 10 × 15 × 3 ft Koi Pond Liner Size and Waterfall GPH
A rectangular pond with 18 inches of spillway.
- 12 × 8 ft Oval Koi Pond Volume and Liner
An oval footprint with different average and maximum depths.
- 4,000-Gallon Koi Pond Pump Flow at 8 ft of Head
About 5,000 GPH of circulation at operating head.
- 24-Inch Pond Waterfall Flow at 150 GPH per Inch
A 24-inch spillway that drives the pump requirement.
- Irregular Koi Pond with Shelves: Volume and EPDM Overlap
A kidney-shaped pond with a deep pocket and shallow shelves.
- 2,500-Gallon Koi Pond UV Clarifier Watts
Compare a per-volume UV estimate with manufacturer ratings.