API 520 / API 526

API 520 pressure relief valve & API 526 orifice calculator

Size an effective relief orifice for critical gas, steam or incompressible liquid and screen API 526 letters D through T.

Inputs

Relieving fluid and pressure
psia
psia
lb/h
°F
lb/lbmol
Effective sizing factors

Results update as inputs change. View results ↑

Screening result

Edit inputs ↓ Live
REQUIRED AREA 0.454 in² API LETTER G SELECTED AREA 0.503 in² UTILIZATION 90.23 % ORIFICE & VALVE Effective areaValve sectionCRITICAL GAS Orifice area headroom PASS SCREEN 0% 100% LIMIT 150%+
0.4539 in² demand / 0.503 in² limit

API letter is based on effective area. Confirm certified capacity, backpressure limits, inlet losses and the relieving scenario before selection.

Export or share
Calculation breakdown
Required effective area
0.4539 in²
API 526 letter
G
Selected API effective area
0.503 in²
Area reserve vs selected or largest letter
0.0491 in²
Required percent of reference area
90.23 %
Required equivalent circular bore
0.7602 in
Inlet to outlet differential
245 psid
Absolute outlet / inlet ratio
7.55 %
Gas critical ratio
52.83 %
US gas coefficient C
356.0604
Napier high-pressure factor Kn
—
Effective reference mass flow
10,528.11 lb/h
Effective reference liquid flow
—

Calculation basis

  1. Gas at critical flow

    Check the absolute outlet-to-inlet ratio against the critical ratio. Use relieving temperature in Rankine in the customary equation. P₁ represents the actual valve inlet under relief, including the applicable overpressure and inlet losses.

    W = C·Kd·P₁·Kb·Kc·A·√(M/(T·Z)) · C = 520√[k(2/(k+1))^((k+1)/(k−1))]

  2. Steam and liquid

    Use Ksh = 1 for saturated steam. The Napier correction Kn applies above 1,500 psia through 3,200 psia. This screen assumes low outlet pressure for steam. The liquid equation uses US gal/min and verified correction factors.

    Wsteam = 51.5·P₁·A·Kd·Kb·Kc·Kn·Ksh · Qliquid = 38·Kd·Kw·Kc·Kv·A·√(ΔP/G)

  3. API effective letter

    Choose the smallest D through T area meeting the computed requirement. If the demand exceeds T, compare against T as a reference and flag the case for engineering review.

    Utilization = 100 × Arequired / Areference

Use an independently established relief load and actual relieving conditions. Verify API 520 method applicability, allowable backpressure and installation, flashing or two-phase flow, valve certification, and manufacturer-rated capacity.

Sources and verification scope ↗