ACI 318-19 §19.2 / §24.2

Long-span beam with sustained load

A 28 ft span under sustained moment illustrates a long-term deflection exceedance.

Edit inputs ↓

Inputs

Editable example

Section
Service load & duration
Gross Ig 13,824in⁴
Cracked Icr 5,377.4in⁴
Effective Ie 5,698.3in⁴
Long-term Δ 2.061in
AnatomyDiagrammatic scale
Parameter-linked deflection drawing. Diagrammatic scale. TRANSFORMED SECTIONRELATIVE STIFFNESSIgIcrIekd 6.83 inℓ 28 ftΔ 2.061 in

Screening

Limit exceeded
Governing deflection utilization147.2%
Bischoff cracked stiffness47.2% over the threshold
  • Immediate live-load incrementΔlive ≤ ℓ/360
    Within limit
  • Total with sustained-load creepΔtotal ≤ ℓ/240 (screening threshold)
    Outside limit

Approximate midspan deflection for prismatic, simply supported members under a uniform load. Limits ℓ/360 for incremental live load and ℓ/240 for total deflection are screening thresholds. Attachment timing and the applicable code limit need project-specific review.

Calculation readout
QuantityValue
Gross concrete inertia Ig13,824 in⁴
Cracked transformed inertia Icr5,377.4 in⁴
Effective total-service inertia Ie5,698.3 in⁴
Total long-term deflection2.061 in
Cracked neutral axis kd6.828 in
Gross centroid from top12 in
Concrete modulus Ec3,605 ksi
Modular ratio n8.044
Modulus of rupture fr474.34 psi
Cracking moment Mcr45.54 kip·ft
Effective cracking threshold30.36 kip·ft
Effective sustained inertia5,698.3 in⁴
Total immediate deflection0.687 in
Sustained immediate deflection0.687 in
Immediate live increment0 in
Additional creep and shrinkage1.374 in
Instantaneous live limit ℓ/3600.933 in
Total screening limit ℓ/2401.4 in
Time multiplier λΔ2

Original example

Worked solution

Default calculator ↗

Starting inputs

Top steel As′
0 in²
Simple span ℓ
28 ft
Sustained moment Ms
100 kip·ft
Added live moment Ml
0 kip·ft

Calculated result

Gross concrete inertia Ig
13,824 in⁴
Cracked transformed inertia Icr
5,377.4 in⁴
Effective total-service inertia Ie
5,698.3 in⁴
Total long-term deflection
2.061 in

With all load sustained, total deflection is immediate deflection multiplied by (1 + λΔ). The live increment is zero.

Preset screening · Bischoff cracked stiffness · Limit exceeded

How the check works

Code basis ↗
  1. Use Ec = 57,000√f′c for normalweight concrete, or 33wc^1.5√f′c with the entered lightweight density. Use Es = 29,000 ksi and n = Es/Ec. Find cracked neutral axis and Icr with equivalent concrete area and no tensile concrete.
  2. Set Mcr = 7.5λ√f′c Ig/yt. Below two-thirds Mcr use Ig; above it interpolate with the squared Bischoff expression in Table 24.2.3.5. Calculate separate stiffnesses at sustained and total moment.
  3. Use Δi = 5 Ma ℓ²/(48 Ec Ie). The live increment is Δtotal,imm − Δsust,imm. Add ξ/(1 + 50ρ′) × Δsust,imm to total immediate deflection.