Inputs
Editable example
Screening
Limit exceeded- Immediate live-load incrementΔlive ≤ ℓ/360Within limit
- Total with sustained-load creepΔtotal ≤ ℓ/240 (screening threshold)Outside limit
Approximate midspan deflection for prismatic, simply supported members under a uniform load. Limits ℓ/360 for incremental live load and ℓ/240 for total deflection are screening thresholds. Attachment timing and the applicable code limit need project-specific review.
Calculation readout
| Quantity | Value |
|---|---|
| Gross concrete inertia Ig | 13,824 in⁴ |
| Cracked transformed inertia Icr | 5,377.4 in⁴ |
| Effective total-service inertia Ie | 5,698.3 in⁴ |
| Total long-term deflection | 2.061 in |
| Cracked neutral axis kd | 6.828 in |
| Gross centroid from top | 12 in |
| Concrete modulus Ec | 3,605 ksi |
| Modular ratio n | 8.044 |
| Modulus of rupture fr | 474.34 psi |
| Cracking moment Mcr | 45.54 kip·ft |
| Effective cracking threshold | 30.36 kip·ft |
| Effective sustained inertia | 5,698.3 in⁴ |
| Total immediate deflection | 0.687 in |
| Sustained immediate deflection | 0.687 in |
| Immediate live increment | 0 in |
| Additional creep and shrinkage | 1.374 in |
| Instantaneous live limit ℓ/360 | 0.933 in |
| Total screening limit ℓ/240 | 1.4 in |
| Time multiplier λΔ | 2 |