ACI 318-19 §19.2 / §24.2

T-beam with a compression flange

A 36 in effective flange shifts the gross centroid and changes the cracked compression shape.

Edit inputs ↓

Inputs

Editable example

Section
Service load & duration
Gross Ig 21,718.7in⁴
Cracked Icr 6,607.6in⁴
Effective Ie 7,041.4in⁴
Long-term Δ 0.927in
AnatomyDiagrammatic scale
Parameter-linked deflection drawing. Diagrammatic scale. TRANSFORMED SECTIONRELATIVE STIFFNESSIgIcrIekd 4.23 inℓ 24 ftΔ 0.927 in

Screening

Within screening limits
Governing deflection utilization77.2%
Bischoff cracked stiffness22.8% below the threshold
  • Immediate live-load incrementΔlive ≤ ℓ/360
    Within limit
  • Total with sustained-load creepΔtotal ≤ ℓ/240 (screening threshold)
    Within limit

Approximate midspan deflection for prismatic, simply supported members under a uniform load. Limits ℓ/360 for incremental live load and ℓ/240 for total deflection are screening thresholds. Attachment timing and the applicable code limit need project-specific review.

Calculation readout
QuantityValue
Gross concrete inertia Ig21,718.7 in⁴
Cracked transformed inertia Icr6,607.6 in⁴
Effective total-service inertia Ie7,041.4 in⁴
Total long-term deflection0.927 in
Cracked neutral axis kd4.228 in
Gross centroid from top9.206 in
Concrete modulus Ec3,605 ksi
Modular ratio n8.044
Modulus of rupture fr474.34 psi
Cracking moment Mcr58.03 kip·ft
Effective cracking threshold38.69 kip·ft
Effective sustained inertia7,720.3 in⁴
Total immediate deflection0.531 in
Sustained immediate deflection0.317 in
Immediate live increment0.214 in
Additional creep and shrinkage0.396 in
Instantaneous live limit ℓ/3600.8 in
Total screening limit ℓ/2401.2 in
Time multiplier λΔ1.25

Original example

Worked solution

Default calculator ↗

Starting inputs

Section shape
T-section (compression flange)
Simple span ℓ
24 ft
Sustained moment Ms
85 kip·ft
Added live moment Ml
45 kip·ft
Sustained duration
12 months (ξ = 1.4)

Calculated result

Gross concrete inertia Ig
21,718.7 in⁴
Cracked transformed inertia Icr
6,607.6 in⁴
Effective total-service inertia Ie
7,041.4 in⁴
Total long-term deflection
0.927 in

Find the gross centroid first. At the cracked section include only concrete in compression, using the flange width over its applicable depth.

Preset screening · Bischoff cracked stiffness · Within limits

How the check works

Code basis ↗
  1. Use Ec = 57,000√f′c for normalweight concrete, or 33wc^1.5√f′c with the entered lightweight density. Use Es = 29,000 ksi and n = Es/Ec. Find cracked neutral axis and Icr with equivalent concrete area and no tensile concrete.
  2. Set Mcr = 7.5λ√f′c Ig/yt. Below two-thirds Mcr use Ig; above it interpolate with the squared Bischoff expression in Table 24.2.3.5. Calculate separate stiffnesses at sustained and total moment.
  3. Use Δi = 5 Ma ℓ²/(48 Ec Ie). The live increment is Δtotal,imm − Δsust,imm. Add ξ/(1 + 50ρ′) × Δsust,imm to total immediate deflection.