Projection geometryA₂ fits within the 1V:2H envelope
Within limit
Concrete bearing strengthPu ≤ φBn
Within limit
Interface reinforcementDowel or continuous steel area ≥ 0.005Ag
Within limit
Concentric compression on a rectangular support with uniform depth. Check the loaded member side, eccentricity, punching, dowel development, shear friction and actual reinforcement load transfer separately.
Take A₁ as loaded width × length. At 1V:2H the uniform side projection is limited by 2 × depth and the nearest support edge. The resulting footprint bounds A₂.
Use φBn = 0.65 × 0.85f′c A₁ × min(√(A₂/A₁), 2). Confinement requires support beyond all loaded edges. Report any Pu above φBn as force requiring a separately designed transfer path.
For a cast-in-place column or pedestal to foundation, compare the provided interface steel with 0.005 times supported gross area. A₁ is the default when it represents the gross area of the supported member.
Centered bearing · rectangular projection · Within screening limits
Inputs
Loaded width
12 in
Loaded length
12 in
Support width
12 in
Support length
12 in
Available projection depth
8 in
Claimed A₂ (0: auto)
0 in²
Concrete strength f′c
4,000 psi
Factored compression Pu
260 kip
Supported Ag (0: use A₁)
0 in²
Dowel bar size
#5
Dowel count (0: none)
4
Calculated values
Design bearing φBn
318.24 kip
Supporting area A₂ used
144 in²
Confinement multiplier
1
Demand beyond concrete bearing
0 kip
Loaded area A₁
144 in²
Maximum projected area A₂
144 in²
Permitted side projection
0 in
Nominal bearing Bn
489.6 kip
Supported gross area Ag
144 in²
Minimum interface steel
0.72 in²
Provided interface steel
1.24 in²
Screening
Basic bearing · Bearing utilization 81.7%
Projection geometry · Within limit
Concrete bearing strength · Within limit
Interface reinforcement · Within limit
Concentric compression on a rectangular support with uniform depth. Check the loaded member side, eccentricity, punching, dowel development, shear friction and actual reinforcement load transfer separately.