Worked example
Quantity estimate for a narrow GFRC sill
Size the material for a narrow GFRC sill and see the review message for a 0.38 water-to-binder ratio.
Edit example inputs
View resultsCasting volume and ingredients
- Outside volume
- 0.1492 ft³4.22 L
- Total displaced volume
- 0 ft³0 L
- Volume in finished casting
- 0.1492 ft³4.22 L
- Volume to mix with allowance
- 0.1626 ft³4.6 L
- Estimated cured mass
- 19.09 lb8.66 kg
- Estimated fresh mix mass
- 21.92 lb9.94 kg
- Portland cement
- 7.63 lb3.46 kg
- Sand
- 8.98 lb4.07 kg
- Coarse aggregate
- 0 lb0 kg
- Pozzolan
- 1.35 lb0.6111 kg
- AR glass fibers
- 0.5481 lb0.2486 kg
- Iron oxide pigment
- 0 lb0 kg
- Mixing water
- 0.409 US gal1.55 L
- GFRC quantities use a simplified sand and binder model. A qualified mix design specifies polymer, fiber and admixtures and accounts for their water and mass.
- This water ratio is above 0.35. Check your validated GFRC mix design for the allowable ratio.
- Cured weight is an estimate from the finished volume. Check actual material yield and use the supplier SDS for cement and silica dust.
Worksheet inputs
- Casting shape
- Rectangular slab
- Slab length
- 47.24 in
- Slab width
- 6.3 in
- Overall thickness or height
- 0.8661 in
- Extra identical cutouts
- 0
- Mixing and waste allowance
- 9%
- Mix type
- GFRC quantity estimate
- Fresh mix density
- 134.84 lb/ft³
- Estimated cured density
- 127.98 lb/ft³
- Water-to-cementitious mass ratio
- 0.38 : 1
- Iron oxide per weight of Portland cement
- 0%
- AR glass fiber in wet GFRC
- 2.5%
- Pozzolan fraction of binder
- 15%
Work through this example
The 4.224 L outside volume needs about 4.604 L with reserve. The warning is a prompt to compare the water ratio with a qualified mix design.
Mix volume = (outside volume − recesses and cutouts) × (1 + waste fraction)The 1:2:3 option uses one part cement, two sand and three aggregate by weight. GFRC uses a simplified 1:1 sand-to-binder estimate with fiber by fresh mass and a selectable pozzolan share. Model water and pigment by mass, then convert water to volume at 1 kg/L. Use a qualified recipe and measured yield for a pour.
Common questions
Can I reduce the water ratio in the sill calculator without changing its dimensions?
Yes. Set the ratio from the qualified mix design. The target volume stays fixed while the estimated batch component weights change.
Should I count ordinary chopped fiberglass as the sill’s AR fiber?
Use fibers specified for alkaline cement matrices by the mix design. Confirm the fiber type and dosage with its manufacturer.