Worked example

Fired size of a terracotta planter

Estimate how a 22 cm terracotta planter changes from wet dimensions to final firing.

Edit example inputs

View results
Piece size
in
in
in
Clay and firing schedule

Wet, bisque and fired dimensions

Total linear shrinkage 8.32%
Wet, bisque and fired profile Total linear shrinkage · 8.32% Front profileWidth at each stageWet · 8.66 inBisque · 8.31 inFired · 7.94 inLength · 8.66 in → 7.94 in22.94% volume loss
Wet, bisque and fired profile · Schematic
Wet length
8.66 in22 cm
Wet width
8.66 in22 cm
Wet height
7.87 in20 cm
Bisque length
8.31 in21.12 cm
Bisque width
8.31 in21.12 cm
Bisque height
7.56 in19.2 cm
Fired length
7.94 in20.17 cm
Fired width
7.94 in20.17 cm
Fired height
7.22 in18.34 cm
Wet to bisque shrinkage
4%
Bisque to final shrinkage
4.5%
Total linear shrinkage
8.32%
Isotropic volume loss
22.94%
  • Shrinkage varies with clay, forming method and firing schedule. Use a test bar fired alongside the work for a close fit.

Work through this example

Example stage losses of 4% and 4.5% leave a final width of about 20.17 cm. Compare the result with a fired sample from your own clay.

Wet dimension = target fired dimension ÷ [(1 − wet-to-bisque loss) × (1 − bisque-to-final loss)]

Each shrinkage percentage is measured relative to the beginning of its stage. Multiply the two retained fractions to move forward, or divide by the product to work backward. Volume retention is the cube of linear retention when shrinkage is uniform in all directions.

Open the main ceramic clay calculator

Common questions

Can I use this planter’s shrinkage rates for a terracotta body from another supplier?

Measure a separate test bar for the second body and firing schedule. The example rates give a starting illustration.

Does the volume loss estimate tell me how much soil the fired planter holds?

The volume loss assumes all axes shrink equally. Estimate soil capacity from the fired internal profile and the actual drainage space.