Total linear shrinkage
8.32%
- Wet length
- 8.66 in22 cm
- Wet width
- 8.66 in22 cm
- Wet height
- 7.87 in20 cm
- Bisque length
- 8.31 in21.12 cm
- Bisque width
- 8.31 in21.12 cm
- Bisque height
- 7.56 in19.2 cm
- Fired length
- 7.94 in20.17 cm
- Fired width
- 7.94 in20.17 cm
- Fired height
- 7.22 in18.34 cm
- Wet to bisque shrinkage
- 4%
- Bisque to final shrinkage
- 4.5%
- Total linear shrinkage
- 8.32%
- Isotropic volume loss
- 22.94%
- Shrinkage varies with clay, forming method and firing schedule. Use a test bar fired alongside the work for a close fit.
Worksheet inputs
- Dimensions entered are
- Wet dimensions
- Length or diameter
- 8.66 in
- Width or second diameter
- 8.66 in
- Height
- 7.87 in
- Clay body
- Terracotta (example rates)
Work through this example
Example stage losses of 4% and 4.5% leave a final width of about 20.17 cm. Compare the result with a fired sample from your own clay.
Wet dimension = target fired dimension ÷ [(1 − wet-to-bisque loss) × (1 − bisque-to-final loss)]Each shrinkage percentage is measured relative to the beginning of its stage. Multiply the two retained fractions to move forward, or divide by the product to work backward. Volume retention is the cube of linear retention when shrinkage is uniform in all directions.
Common questions
Can I use this planter’s shrinkage rates for a terracotta body from another supplier?
Measure a separate test bar for the second body and firing schedule. The example rates give a starting illustration.
Does the volume loss estimate tell me how much soil the fired planter holds?
The volume loss assumes all axes shrink equally. Estimate soil capacity from the fired internal profile and the actual drainage space.