RO4350B 10 mil 50 Ω Microstrip Width
Calculate a 50 Ω trace on 10 mil RO4350B with design Dk 3.66, half-ounce copper and a 5.8 GHz guided wavelength.
Results
Preset estimateQuasi-static cross-section
- Width for 50 Ω
- 0.5368 mm
- Effective εr
- 2.808
- Propagation delay
- 5.59 ps/mm
Line properties
- Difference from target
- -0.18 Ω
- Finished copper
- 17.4 µm
- Effective strip width
- 0.5593 mm
- Guided wavelength
- 30.846 mm
- Guided quarter wave
- 7.711 mm
Worked example
The 10 mil dielectric height is 0.254 mm. Rogers quotes 3.66 as the design dielectric constant for RO4350B. Enter finished copper thickness through the ounces field and compare the calculated value with the target width.
Wavelength is shortened by the effective permittivity of the line. Here the delay and wavelength are quasi-static estimates. Precision layouts at 5.8 GHz benefit from the fabricator’s actual material and dispersion model.
- Characteristic impedance Z₀
- 49.82 Ω
- Width for 50 Ω
- 0.5368 mm
- Effective εr
- 2.808
- Propagation delay
- 5.59 ps/mm
Formulas & assumptions
- Microstrip uses the Hammerstad–Jensen quasi-static equations with finite-thickness correction on normalized width W/h.
- CPW and grounded CPW use Ghione–Naldi conformal mapping and K(k)/K(k′), including a first-order copper thickness correction. Backside ground changes the substrate contribution.
- Copper thickness ≈ 0.03479 mm per oz/ft². Delay = √εeff / c. Guided wavelength = c / (f√εeff).
- Target trace width is solved numerically inside the geometry range of the selected model.
These cross-sections omit solder mask, trace taper, roughness, finite side-ground width, launch discontinuities and high-frequency dispersion. Use the fab’s actual finished stackup and impedance solver for production.
CPW requires a gap wide enough for the finite-copper correction. Use the same topology as the fabricated board, including the presence or absence of the reference plane.
References
Questions & answers
Why does the RO4350B example use 3.66 instead of 3.48?
Rogers distinguishes design Dk of 3.66 from a typical process Dk of 3.48. Use the value appropriate to the line model and material data.
How do I enter 10 mil RO4350B into a millimeter calculator?
Enter 0.254 mm for the dielectric height. One mil is 0.0254 mm.